中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Quantum efficiency calibration for low energy detector onboard hard X-ray modulation telescope satellite

文献类型:期刊论文

作者Cui WW(崔苇苇); Zhu Y(朱玥); Zhang ZL(张子良); Yang YJ(杨彦佶); Xue RF(薛荣峰); Lu B(陆波); Wang J(王娟); Chen TX(陈田祥); Wang YS(王于仨); Li W(李炜)
刊名ACTA PHYSICA SINICA
出版日期2017
卷号66期号:11页码:112901
关键词charge-coupled device quantum efficiency depletion region
ISSN号1000-3290
DOI10.7498/aps.66.112901
其他题名硬X射线调制望远镜低能探测器量子效率标定
英文摘要Low energy X-ray telescope, working over 0.7-15 keV energy band, is one of the main payloads in the hard X-ray modulation telescope satellite. The primary scientific objectives are to survey large sky area to investigate galactic X-ray transient sources as well as the cosmic X-ray background, and to observe X-ray binaries or black holes for studying the dynamics and emission mechanism in strong gravitational or magnetic field. The detector of low energy X-ray telescope is CCD236, a new generation of swept charge device, which has good time and energy resolution. Quantum efficiency (QE) of the detector has a crucial influence on X-ray spectrum fitting and absolute luminosity calculation. To provide valuable scientific data, QE should be calibrated in detail. In this paper, QE calibration is accomplished with respect to a silicon drift detector (SDD), using an Fe-55 radioactive source, at energy points Mn-K-alpha (5.899 keV) and Mn-K-beta (6.497 keV). The energies of Mn-K-alpha and Mn-K-beta are near that of iron-K, which is an important line in X-ray observation. Additionally, Mn-K-alpha and Mn-K-beta X-ray will partially pass through the depletion region of CCD236, and these energy points can be used to measure the depletion thickness. This experiment is set up in a vacuum cooling chamber. The X-ray source perpendicularly illuminates SDD and CCD236 through a small hole, whose area is far less than those of two detectors; therefore, QE measurements are irrelevant to neither the distance nor the azimuth angle between the X-ray source and the detector. For CCD236, split events should be corrected. Energy spectra of SDD and CCD236 are fitted with two Gaussian distributions, respectively, to obtain peak positions and standard variations of Mn-K-alpha and Mn-K-beta. With known structure of SDD, the QE of CCD236 can be calculated. QE values at Mn-K-alpha and Mn-K-beta are 71% and 62%, respectively. QE and temperature are uncorrelated with each other in a temperature range from -95 degrees C to -30 degrees C. According to the specific structure of CCD236 and the measured QE, without considering the effect of channel stop, the best-fit thickness of depletion region is obtained to be 38 mu m. When CCD236 is applied with different driving or substrate voltages, no obvious variation of QE is observed. It indicates that the thickness values of depletion region with high and low level voltages are equal. Furthermore, it shows that working CCD236 is deep depleted, and the thickness of depletion region will not change because it reaches its maximum, the edge of epitaxial layer and substrate layer.
WOS研究方向Physics, Multidisciplinary
语种中文
WOS记录号WOS:000403091100007
源URL[http://ir.ihep.ac.cn/handle/311005/282187]  
专题高能物理研究所_粒子天体物理中心
高能物理研究所_实验物理中心
硬X射线调制望远镜卫星
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Cui WW,Zhu Y,Zhang ZL,et al. Quantum efficiency calibration for low energy detector onboard hard X-ray modulation telescope satellite[J]. ACTA PHYSICA SINICA,2017,66(11):112901.
APA 崔苇苇.,朱玥.,张子良.,杨彦佶.,薛荣峰.,...&Chen TX.(2017).Quantum efficiency calibration for low energy detector onboard hard X-ray modulation telescope satellite.ACTA PHYSICA SINICA,66(11),112901.
MLA 崔苇苇,et al."Quantum efficiency calibration for low energy detector onboard hard X-ray modulation telescope satellite".ACTA PHYSICA SINICA 66.11(2017):112901.

入库方式: OAI收割

来源:高能物理研究所