Fast and accurate generation method of PSF-based system matrix for PET reconstruction

文献类型:期刊论文

作者Tang, HH; Chai, P; Li, MH; Gao, J; Li, DW; Yun, MK; Liu, SQ; Sun, XL; Wei L(魏龙); Zhang ZM(章志明)
刊名CHINESE PHYSICS C中国物理. C
出版日期2017
卷号41期号:4页码:48201
关键词PSF P-SPIR system matrix GATE PET reconstruction
ISSN号1674-1137
DOI10.1088/1674-1137/41/4/048201
文献子类Article
英文摘要This work investigates the positional single photon incidence response (P-SPIR) to provide an accurate point spread function (PSF)-contained system matrix and its incorporation within the image reconstruction framework. Based on the Geant4 Application for Emission Tomography (GATE) simulation, P-SPIR theory takes both incidence angle and incidence position of the gamma photon into account during crystal subdivision, instead of only taking the former into account, as in single photon incidence response (SPIR). The response distribution obtained in this fashion was validated using Monte Carlo simulations. In addition, two-block penetration and normalization of the response probability are introduced to improve the accuracy of the PSF. With the incorporation of the PSF, the homogenization model is then analyzed to calculate the spread distribution of each line-of-response (LOR). A primate PET scanner, Eplus-260, developed by the Institute of High Energy Physics, Chinese Academy of Sciences (IHEP), was employed to evaluate the proposed method. The reconstructed images indicate that the P-SPIR method can effectively mitigate the depth-of-interaction (DOI) effect, especially at the peripheral area of field-of-view (FOV). Furthermore, the method can be applied to PET scanners with any other structures and list-mode data format with high flexibility and efficiency.
WOS关键词POINT-SPREAD FUNCTION ; IMAGE-RECONSTRUCTION ; SIMULATION ; RESOLUTION ; SCANNER ; VALIDATION ; DETECTOR ; GPU
WOS研究方向Physics
语种英语
CSCD记录号CSCD:5954046
WOS记录号WOS:000400124800025
源URL[http://ir.ihep.ac.cn/handle/311005/284748]  
专题高能物理研究所_核技术应用研究中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Tang, HH,Chai, P,Li, MH,et al. Fast and accurate generation method of PSF-based system matrix for PET reconstruction[J]. CHINESE PHYSICS C中国物理. C,2017,41(4):48201.
APA Tang, HH.,Chai, P.,Li, MH.,Gao, J.,Li, DW.,...&Zhang, ZM.(2017).Fast and accurate generation method of PSF-based system matrix for PET reconstruction.CHINESE PHYSICS C中国物理. C,41(4),48201.
MLA Tang, HH,et al."Fast and accurate generation method of PSF-based system matrix for PET reconstruction".CHINESE PHYSICS C中国物理. C 41.4(2017):48201.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。