In situ experimental study on thermal protection effects of the insulation method on warm permafrost
文献类型:期刊论文
作者 | Wen, Zhi; Sheng, Yu; Ma, Wei; Qi, Jilin |
刊名 | COLD REGIONS SCIENCE AND TECHNOLOGY
![]() |
出版日期 | 2008-08-01 |
卷号 | 53期号:3页码:369-381 |
关键词 | Qinghai-Tibetan railway Permafrost regions Thermal insulated treatment Ground temperature |
ISSN号 | 0165-232X |
DOI | 10.1016/j.coldregions.2007.06.004 |
通讯作者 | Wen, Zhi(wenzhi@lzb.ac.cn) |
英文摘要 | To evaluate the thermal protection effects of the insulation treatment, a 307 in long railway test section was constructed on the Qinghai-Tibetan plateau in 2001. Over 5 years observation data were collected and analyzed. The results showed that there was an obvious temperature difference between the top and the bottom of the insulation. The temperature of the deep permafrost rose for both the expanded polystyrene (EPS) and polyurethane foam (PU) sections due to the embankment construction. Because the soil temperature at the depth of 0.5 m below the south facing slope was much higher than that of the north facing slope and was a few degrees higher than that of the embankment surface, the permafrost temperature under the south facing slope rose, and the permafrost temperature under the centre of the embankment remained unchanged, and the permafrost temperature under the north facing slope dropped. Accordingly, the artificial permafrost table under the center of the embankment did not change, while the artificial permafrost table under the northern slope rose, and the artificial permafrost table under the southern slope declined. The experiment indicated that the insulation method was suitable for permafrost regions with low embankment surface temperature and it was not suitable for warm permafrost regions with high embankment surface temperature. (C) 2007 Elsevier B. V. All rights reserved. |
收录类别 | SCI |
WOS研究方向 | Engineering ; Geology |
WOS类目 | Engineering, Environmental ; Engineering, Civil ; Geosciences, Multidisciplinary |
语种 | 英语 |
WOS记录号 | WOS:000260040200012 |
出版者 | ELSEVIER SCIENCE BV |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2556128 |
专题 | 寒区旱区环境与工程研究所 |
通讯作者 | Wen, Zhi |
作者单位 | CAS, CAREERI, State Key Lab Frozen Soil Engn, Lanzhou 730000, Gansu, Peoples R China |
推荐引用方式 GB/T 7714 | Wen, Zhi,Sheng, Yu,Ma, Wei,et al. In situ experimental study on thermal protection effects of the insulation method on warm permafrost[J]. COLD REGIONS SCIENCE AND TECHNOLOGY,2008,53(3):369-381. |
APA | Wen, Zhi,Sheng, Yu,Ma, Wei,&Qi, Jilin.(2008).In situ experimental study on thermal protection effects of the insulation method on warm permafrost.COLD REGIONS SCIENCE AND TECHNOLOGY,53(3),369-381. |