中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Numerical study of long-term cooling effects of thermosyphons around tower footings in permafrost regions along the Qinghai-Tibet Power Transmission Line

文献类型:期刊论文

作者Mu, Yanhu; Li, Guoyu; Yu, Qihao; Ma, Wei; Wang, Dayan; Wang, Fei
刊名COLD REGIONS SCIENCE AND TECHNOLOGY
出版日期2016
卷号121页码:237-249
关键词Tower footing Thermosyphons Foundation soils Permafrost Qinghai-Tibet Power Transmission Line
ISSN号0165-232X
DOI10.1016/j.coldregions.2015.06.005
通讯作者Yu, Qihao(yuqh@lzb.ac.cn)
英文摘要Two-phase closed thermosyphons are extensively used for cooling foundation soils of tower footings in permafrost regions along the Qinghai-Tibet Power Transmission Line (QTPTL). In this paper, the working period of these thermosyphons is firstly determined by field observations. Then, a 3-D numerical heat transfer model is constructed to study the long-term cooling effects of thermosyphons and thermal performance of foundation soils. The numerically simulated results show a significant cooling of foundation soils near thermosyphons in cold season approximately from late October to early May, and a rapid shift of the thermosyphon cooling to the footing side due to greater thermal conductivity of the concrete footing. As a consequence, a colder bulb would develop under the footing, increasing the bearing capacity of foundation soils. In warm season from the mid-May to mid-October, the maximum thaw around the footing would be greater than that in the natural ground due to better heat transfer through the concrete footing. During a 50-year operational period, foundation soils under the footing would roughly go through about four thermal stages under a combined effect of the thermosyphon cooling and climate warming: a rapid cooling stage in the first to 5th year, a stable stage in the 6th-15th year, a rapid warming stage in the 16th-35th year and a slow warming stage after the 35th year. During the operational period, the maximum thaw around the footing would be less than the embedding depth of the footing (5.8 m), meeting the design criterion for thermal stability of foundation soils. (C) 2015 Elsevier B.V. All rights reserved.
收录类别SCI
WOS关键词2-PHASE CLOSED THERMOSIPHON ; EMBANKMENT ; RAILWAY ; HIGHWAY
WOS研究方向Engineering ; Geology
WOS类目Engineering, Environmental ; Engineering, Civil ; Geosciences, Multidisciplinary
语种英语
WOS记录号WOS:000367111400024
出版者ELSEVIER SCIENCE BV
URI标识http://www.irgrid.ac.cn/handle/1471x/2557164
专题寒区旱区环境与工程研究所
通讯作者Yu, Qihao
作者单位Chinese Acad Sci, Cold & Arid Reg Environm & Engn Res Inst, State Key Lab Frozen Soils Engn, Lanzhou 730000, Peoples R China
推荐引用方式
GB/T 7714
Mu, Yanhu,Li, Guoyu,Yu, Qihao,et al. Numerical study of long-term cooling effects of thermosyphons around tower footings in permafrost regions along the Qinghai-Tibet Power Transmission Line[J]. COLD REGIONS SCIENCE AND TECHNOLOGY,2016,121:237-249.
APA Mu, Yanhu,Li, Guoyu,Yu, Qihao,Ma, Wei,Wang, Dayan,&Wang, Fei.(2016).Numerical study of long-term cooling effects of thermosyphons around tower footings in permafrost regions along the Qinghai-Tibet Power Transmission Line.COLD REGIONS SCIENCE AND TECHNOLOGY,121,237-249.
MLA Mu, Yanhu,et al."Numerical study of long-term cooling effects of thermosyphons around tower footings in permafrost regions along the Qinghai-Tibet Power Transmission Line".COLD REGIONS SCIENCE AND TECHNOLOGY 121(2016):237-249.

入库方式: iSwitch采集

来源:寒区旱区环境与工程研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。