中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Direct detection of potassium and lead (II) ions based on assembly- disassembly of a chiral cyanine dye /TBA complex

文献类型:期刊论文

作者Shen, Gang; Zhang, Hong; Xiang, Junfeng; Yang, Fengmin; Wu, Shuling; Wang, Wei; Du, Ning; Zhang, Jinghua; Sun, Tao; Tang, Yalin
刊名TALANTA
出版日期2019-08-15
卷号201页码:490-495
ISSN号0039-9140
DOI10.1016/j.talanta.2019.04.032
英文摘要A highly selective and sensitive direct detection of potassium (K+) and lead (Pb2+) ions was developed by using the assembly and disassembly of a chiral cyanine dye/TBA complex. The dye DMSB (3-ethyl-2-[3-(3-ethyl-3H-benzoselenazol-2-ylidene)-2-methylprop-1-enyl] benzoselenazolium bromide) loses the ability of self-assembly, but it can be activated by thrombin-binding aptamer (TBA) G-quadruplex structure. And only the TBA G-quadruplex formed in the presence of K + , can strongly induce J-aggregate signals of DMSB. Because the Pb2+ ions can bind and stabilize the TBA G-quadruplex with much higher efficiency than K+, the J-aggregate signals of DMSB falls sharply when the Pb2+ is present. As a result, the assembly and disassembly of DMSB allows the selective detection of 10 mu M K+ and 20 nM Pb2+ respectively, even the competitive sodium ion (Na+) was as high as 145 mM. The linear correlation existed between the J-aggregate intensity and the concentration of K+ and Pb2+ over the range of 0.5-5.0 mM and 200-2000 nM, respectively. Moreover, the concentration of K+ (similar to 3 mM) and Pb2+ (below 20 nM) in human blood serum samples were determined by the present method, which agreed well with inductively coupled plasma mass spectrometry (ICP-MS). This work not only opens a door for the further development of G-quadruplex-based aptasensor in complex real system, but also provides a simple and versatile sensing platform for ion detection in clinic.
语种英语
WOS记录号WOS:000471084300066
源URL[http://ir.iccas.ac.cn/handle/121111/82660]  
专题中国科学院化学研究所
作者单位Chinese Acad Sci, Inst Chem, Beijing 100190, Peoples R China
推荐引用方式
GB/T 7714
Shen, Gang,Zhang, Hong,Xiang, Junfeng,et al. Direct detection of potassium and lead (II) ions based on assembly- disassembly of a chiral cyanine dye /TBA complex[J]. TALANTA,2019,201:490-495.
APA Shen, Gang.,Zhang, Hong.,Xiang, Junfeng.,Yang, Fengmin.,Wu, Shuling.,...&Tang, Yalin.(2019).Direct detection of potassium and lead (II) ions based on assembly- disassembly of a chiral cyanine dye /TBA complex.TALANTA,201,490-495.
MLA Shen, Gang,et al."Direct detection of potassium and lead (II) ions based on assembly- disassembly of a chiral cyanine dye /TBA complex".TALANTA 201(2019):490-495.

入库方式: OAI收割

来源:化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。