Performance of SiPMs and pre-amplifier for the wide field of view Cherenkov telescope array of LHAASO

文献类型:期刊论文

作者Bi BY(毕白洋); Heller, M; della Volpe, D; Montaruli, T; Wang, C; Ma, LL; Yin, LQ; Cao, Z; Zhang, SS; Bi, BY
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
出版日期2018
卷号899页码:94-100
关键词Silicon photomultiplier Dynamic range Pre-amplifier LHAASO WFCTA
ISSN号0168-9002
DOI10.1016/j.nima.2018.05.019
文献子类Article
英文摘要The Wide Field of View Cherenkov Telescope Array (WFCTA), a main component of the Large High Altitude Air Shower Observatory (LHAASO), is designed for cosmic rays spectrum measurement from 30 TeV to several EeV. Silicon photomultipliers (SiPMs) have been adopted for the telescope cameras as they do not suffer any aging even with strong light exposure and thus they can be operated with moonlight. The physics of WFCTA requires a dynamic range of SiPMs to be within 10 p.e. (photoelectrons) to 32, 000 p.e. at any energy range. And the dynamic range of SiPMs is proportional to the total number of APDs and depends on the distribution of light hitting on the active area. This light distribution is affected by the use of light concentrator and also by the use of spherical mirrors of the telescope. The effect of these two factors on the Cherenkov light distribution has to be taken into account to evaluate the dynamic range and in this work they have been simulated with a ray-tracing software. The non-uniform light distribution caused by the light concentrator and the spherical mirror will be below 2% for 32, 000 p.e. at the condition if the SiPM has 360, 000 cells. The characteristics of SiPMs from three different producers - Hamamatsu, FBK, and SensL - are measured in laboratory, and the dynamic range of them has also been measured using a uniform light flux. The results of dynamic range correspond with the calculation by the function which describes the relationship between the number of fired APDs and the total number of APDs in the SiPM. The performance of the SiPMs and PMTs under long time duration light pulses up to 3 mu s are compared, in order to investigate the stability of the gain of the SiPMs for the fluorescence mode.
电子版国际标准刊号1872-9576
WOS研究方向Instruments & Instrumentation ; Nuclear Science & Technology ; Physics
语种英语
WOS记录号WOS:000436488100015
源URL[http://ir.ihep.ac.cn/handle/311005/286068]  
专题高能物理研究所_粒子天体物理中心
通讯作者Bi BY(毕白洋)
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Bi BY,Heller, M,della Volpe, D,et al. Performance of SiPMs and pre-amplifier for the wide field of view Cherenkov telescope array of LHAASO[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2018,899:94-100.
APA 毕白洋.,Heller, M.,della Volpe, D.,Montaruli, T.,Wang, C.,...&张寿山.(2018).Performance of SiPMs and pre-amplifier for the wide field of view Cherenkov telescope array of LHAASO.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,899,94-100.
MLA 毕白洋,et al."Performance of SiPMs and pre-amplifier for the wide field of view Cherenkov telescope array of LHAASO".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 899(2018):94-100.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。