Performance of beam size monitor based on Kirkpatrick-Baez mirror at SSRF
文献类型:期刊论文
; | |
作者 | Zhu DC(祝德充)![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
刊名 | NUCLEAR SCIENCE AND TECHNIQUES
![]() ![]() |
出版日期 | 2018 ; 2018 |
卷号 | 29期号:10页码:148 |
关键词 | KB mirror KB mirror Beam size measurement Beam diagnostic Emittance Synchrotron radiation Beam size measurement Beam diagnostic Emittance Synchrotron radiation |
ISSN号 | 1001-8042 ; 1001-8042 |
DOI | 10.1007/s41365-018-0477-y ; 10.1007/s41365-018-0477-y |
文献子类 | Article ; Article |
英文摘要 | High-energy photon source (HEPS) is a 6GeV ultralow emittance storage ring light source to be built in Beijing, China. Both the horizontal and vertical beam sizes of the HEPS storage ring are below 10 mu m. It is a challenge to measure such a small beam size in both directions. To this end, measurement by a Kirkpatrick-Baez (KB) mirror imaging system was evaluated. A test KB system for the Shanghai Synchrotron Radiation Facility storage ring was designed and tested. Two crossed cylindrical mirrors were used to image the dipole source point. Both mirrors can be moved in and out so that the monitor is interchangeable with the original X-ray pinhole monitor. The aberration and point spread function, which would cause image blur, were evaluated. A beam-based calibration scheme was used by varying the beam size with different quadrupole settings and fitting them with the corresponding theoretical values. We updated the original X-ray camera with a new camera having a 5-m-thick LuAG/Ce scintillator, and the imaging result shows greatly decreased image blur.; High-energy photon source (HEPS) is a 6GeV ultralow emittance storage ring light source to be built in Beijing, China. Both the horizontal and vertical beam sizes of the HEPS storage ring are below 10 mu m. It is a challenge to measure such a small beam size in both directions. To this end, measurement by a Kirkpatrick-Baez (KB) mirror imaging system was evaluated. A test KB system for the Shanghai Synchrotron Radiation Facility storage ring was designed and tested. Two crossed cylindrical mirrors were used to image the dipole source point. Both mirrors can be moved in and out so that the monitor is interchangeable with the original X-ray pinhole monitor. The aberration and point spread function, which would cause image blur, were evaluated. A beam-based calibration scheme was used by varying the beam size with different quadrupole settings and fitting them with the corresponding theoretical values. We updated the original X-ray camera with a new camera having a 5-m-thick LuAG/Ce scintillator, and the imaging result shows greatly decreased image blur. |
电子版国际标准刊号 | 2210-3147 ; 2210-3147 |
WOS关键词 | RAY PINHOLE CAMERA ; RAY PINHOLE CAMERA ; SYNCHROTRON-RADIATION ; SYNCHROTRON-RADIATION |
WOS研究方向 | Nuclear Science & Technology ; Nuclear Science & Technology ; Physics ; Physics |
语种 | 英语 ; 英语 |
CSCD记录号 | CSCD:6340472 ; CSCD:6340472 |
WOS记录号 | WOS:000445809700007 ; WOS:000445809700007 |
源URL | [http://ir.ihep.ac.cn/handle/311005/286363] ![]() |
专题 | 高能物理研究所_加速器中心 高能同步辐射光源 |
作者单位 | 中国科学院高能物理研究所 |
推荐引用方式 GB/T 7714 | Zhu DC,Yue JH,Sui YF,et al. Performance of beam size monitor based on Kirkpatrick-Baez mirror at SSRF, Performance of beam size monitor based on Kirkpatrick-Baez mirror at SSRF[J]. NUCLEAR SCIENCE AND TECHNIQUES, NUCLEAR SCIENCE AND TECHNIQUES,2018, 2018,29, 29(10):148, 148. |
APA | 祝德充.,岳军会.,隋艳峰.,季大恒.,曹建社.,...&Leng, YB.(2018).Performance of beam size monitor based on Kirkpatrick-Baez mirror at SSRF.NUCLEAR SCIENCE AND TECHNIQUES,29(10),148. |
MLA | 祝德充,et al."Performance of beam size monitor based on Kirkpatrick-Baez mirror at SSRF".NUCLEAR SCIENCE AND TECHNIQUES 29.10(2018):148. |
入库方式: OAI收割
来源:高能物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。