A method for aligning the plastic scintillator detector on DAMPE
文献类型:期刊论文
作者 | Ma, Peng-Xiong1,2; Zhang, Yong-Jie3,4,5; Zhang, Ya-Peng3; Li, Yao3; Zang, Jing-Jing1![]() ![]() ![]() ![]() ![]() |
刊名 | RESEARCH IN ASTRONOMY AND ASTROPHYSICS
![]() |
出版日期 | 2019-06-01 |
卷号 | 19期号:6页码:8 |
关键词 | instrumentation: detectors methods: data analysis |
ISSN号 | 1674-4527 |
DOI | 10.1088/1674-4527/19/6/82 |
通讯作者 | Zhang, Ya-Peng(y.p.zhang@impcas.ac.cn) |
英文摘要 | The Plastic Scintillator Detector (PSD) onboard the DArk Matter Particle Explorer (DAMPE) is designed to measure cosmic ray charge (Z) and to act as a veto detector for gamma ray identification. To fully exploit the charge identification potential of PSD and to enhance its capability to identify gamma ray events, we develop an alignment method for the PSD. The path length of a given track in the volume of a PSD bar is derived taking into account the shift and rotation alignment corrections. By examining energy spectra of corner-passing events and fully contained events, position shifts and rotations of all PSD bars are obtained, and are found to be on average about 1 mm and 0.0015 radian respectively. To validate the alignment method, we introduce artificial shifts and rotations of PSD bars into the detector simulation. These shift and rotation parameters can be recovered successfully by the alignment procedure. As a result of the PSD alignment procedure, the charge resolution of the PSD is improved from 4% to 8%, depending on the nuclei. |
WOS研究方向 | Astronomy & Astrophysics |
语种 | 英语 |
WOS记录号 | WOS:000470875400007 |
出版者 | NATL ASTRONOMICAL OBSERVATORIES, CHIN ACAD SCIENCES |
源URL | [http://libir.pmo.ac.cn/handle/332002/27502] ![]() |
专题 | 中国科学院紫金山天文台 |
通讯作者 | Zhang, Ya-Peng |
作者单位 | 1.Chinese Acad Sci, Purple Mt Observ, Key Lab Dark Matter & Space Astron, Nanjing 210008, Jiangsu, Peoples R China 2.Univ Sci & Technol China, Sch Astron & Space Sci, Hefei 230026, Anhui, Peoples R China 3.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Gansu, Peoples R China 4.Lanzhou Univ, Sch Nucl Sci & Technol, Lanzhou 730000, Gansu, Peoples R China 5.Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Ma, Peng-Xiong,Zhang, Yong-Jie,Zhang, Ya-Peng,et al. A method for aligning the plastic scintillator detector on DAMPE[J]. RESEARCH IN ASTRONOMY AND ASTROPHYSICS,2019,19(6):8. |
APA | Ma, Peng-Xiong.,Zhang, Yong-Jie.,Zhang, Ya-Peng.,Li, Yao.,Zang, Jing-Jing.,...&Sun, Zhi-Yu.(2019).A method for aligning the plastic scintillator detector on DAMPE.RESEARCH IN ASTRONOMY AND ASTROPHYSICS,19(6),8. |
MLA | Ma, Peng-Xiong,et al."A method for aligning the plastic scintillator detector on DAMPE".RESEARCH IN ASTRONOMY AND ASTROPHYSICS 19.6(2019):8. |
入库方式: OAI收割
来源:紫金山天文台
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。