关键词Capillary Pumped Loop Heat Pipe Evaporator
英文摘要The disturbance, caused by the boiling phenomena in the inverted meniscus type evaporator, is of great importance in the normal operation of the CPL, especially when the heat load is low. By theoretical and experimental studies on this issue, it shows that the evaporator of the CPL operates in a mode of boiling in the wick. By solving a set of momentum equations, it concludes that, this kind of boiling phenomena in the wick cause no notable negative influence on the normal performance of the CPL, although there really exists some adverse influence during the CPL start-up. Additionally, the causes of the dry-out of the evaporator under low heat load are conducted in the paper. The conclusions are verified by subsequent experiments. More details about the experiments are also described in the paper.
公开日期2013-03-12
源URL[http://ir.etp.ac.cn/handle/311046/53912]  
专题工程热物理研究所_Journal of Thermal Science
推荐引用方式
GB/T 7714
Zhang Jiaxun,Hou Zengqi. The Effect of Disturbance in the Evaporator on the Performance of Capillary Pumped Loop (CPL)[J]. JOURNAL OF THERMAL SCIENCE,1999,8(2):120,124.
APA Zhang Jiaxun,&Hou Zengqi.(1999).The Effect of Disturbance in the Evaporator on the Performance of Capillary Pumped Loop (CPL).JOURNAL OF THERMAL SCIENCE,8(2),120,124.
MLA Zhang Jiaxun,et al."The Effect of Disturbance in the Evaporator on the Performance of Capillary Pumped Loop (CPL)".JOURNAL OF THERMAL SCIENCE 8.2(1999):120,124.

入库方式: OAI收割

来源:工程热物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。