A unique hybrid-structured surface produced by rapid electrochemical anodization enhances bio-corrosion resistance and bone cell responses of beta-type Ti-24Nb-4Zr-8Sn alloy
文献类型:期刊论文
作者 | Liu, CF; Lee, TH; Liu, JF; Hou, WT; Li, SJ; Hao, YL; Pan, HB; Huang, HH; Huang, HH (reprint author), Natl Yang Ming Univ, Inst Oral Biol, Taipei, Taiwan.; Huang, HH (reprint author), Natl Yang Ming Univ, Dept Dent, Taipei, Taiwan. |
刊名 | SCIENTIFIC REPORTS
![]() |
出版日期 | 2018-04-26 |
卷号 | 8页码:- |
关键词 | Elastic-deformation Behavior Biomedical Titanium-alloys Mechanical-properties In-vitro Osteoblast Differentiation Nanoscale Topography Protein Adsorption Orthodontic Wires Anodic-oxidation Focal Adhesion |
ISSN号 | 2045-2322 |
英文摘要 | Ti-24Nb-4Zr-8Sn (Ti2448), a new beta-type Ti alloy, consists of nontoxic elements and exhibits a low uniaxial tensile elastic modulus of approximately 45 GPa for biomedical implant applications. Nevertheless, the bio-corrosion resistance and biocompatibility of Ti2448 alloys must be improved for long-term clinical use. In this study, a rapid electrochemical anodization treatment was used on Ti2448 alloys to enhance the bio-corrosion resistance and bone cell responses by altering the surface characteristics. The proposed anodization process produces a unique hybrid oxide layer (thickness 50-120 nm) comprising a mesoporous outer section and a dense inner section. Experiment results show that the dense inner section enhances the bio-corrosion resistance. Moreover, the mesoporous surface topography, which is on a similar scale as various biological species, improves the wettability, protein adsorption, focal adhesion complex formation and bone cell differentiation. Outside-in signals can be triggered through the interaction of integrins with the mesoporous topography to form the focal adhesion complex and to further induce osteogenic differentiation pathway. These results demonstrate that the proposed electrochemical anodization process for Ti2448 alloys with a low uniaxial tensile elastic modulus has the potential for biomedical implant applications.; Ti-24Nb-4Zr-8Sn (Ti2448), a new beta-type Ti alloy, consists of nontoxic elements and exhibits a low uniaxial tensile elastic modulus of approximately 45 GPa for biomedical implant applications. Nevertheless, the bio-corrosion resistance and biocompatibility of Ti2448 alloys must be improved for long-term clinical use. In this study, a rapid electrochemical anodization treatment was used on Ti2448 alloys to enhance the bio-corrosion resistance and bone cell responses by altering the surface characteristics. The proposed anodization process produces a unique hybrid oxide layer (thickness 50-120 nm) comprising a mesoporous outer section and a dense inner section. Experiment results show that the dense inner section enhances the bio-corrosion resistance. Moreover, the mesoporous surface topography, which is on a similar scale as various biological species, improves the wettability, protein adsorption, focal adhesion complex formation and bone cell differentiation. Outside-in signals can be triggered through the interaction of integrins with the mesoporous topography to form the focal adhesion complex and to further induce osteogenic differentiation pathway. These results demonstrate that the proposed electrochemical anodization process for Ti2448 alloys with a low uniaxial tensile elastic modulus has the potential for biomedical implant applications. |
学科主题 | Multidisciplinary Sciences |
语种 | 英语 |
资助机构 | Ministry of Science and Technology, Taiwan [MOST 98-2314-B-010-011-MY3, 104-2221-E-040-003, 105-2221-E-040-001]; Chinese MOST [2017YFC1104901, 2016YFC110261]; Key Research Program of Frontier Sciences, CAS [QYZDJ-SSWJSC031-02]; National Natural Science Foundation of China [51591190, 51771209, 51631007]; Shenzhen Peacock Program [110811003586331] |
公开日期 | 2018-06-05 |
源URL | [http://ir.imr.ac.cn/handle/321006/79355] ![]() |
专题 | 金属研究所_中国科学院金属研究所 |
通讯作者 | Huang, HH (reprint author), Natl Yang Ming Univ, Inst Oral Biol, Taipei, Taiwan.; Huang, HH (reprint author), Natl Yang Ming Univ, Dept Dent, Taipei, Taiwan.; Huang, HH (reprint author), China Med Univ, Grad Inst Basic Med Sci, Taichung, Taiwan.; Huang, HH (reprint author), China Med Univ Hosp, Dept Med Res, Taichung, Taiwan.; Huang, HH (reprint author), Asia Univ, Dept Bioinformat & Med Engn, Taichung, Taiwan.; Huang, HH (reprint author), Taipei Vet Gen Hosp, Dept Stomatol, Taipei, Taiwan.; Huang, HH (reprint author), Taipei City Hosp, Dept Educ & Res, Taipei, Taiwan. |
推荐引用方式 GB/T 7714 | Liu, CF,Lee, TH,Liu, JF,et al. A unique hybrid-structured surface produced by rapid electrochemical anodization enhances bio-corrosion resistance and bone cell responses of beta-type Ti-24Nb-4Zr-8Sn alloy[J]. SCIENTIFIC REPORTS,2018,8:-. |
APA | Liu, CF.,Lee, TH.,Liu, JF.,Hou, WT.,Li, SJ.,...&Huang, HH .(2018).A unique hybrid-structured surface produced by rapid electrochemical anodization enhances bio-corrosion resistance and bone cell responses of beta-type Ti-24Nb-4Zr-8Sn alloy.SCIENTIFIC REPORTS,8,-. |
MLA | Liu, CF,et al."A unique hybrid-structured surface produced by rapid electrochemical anodization enhances bio-corrosion resistance and bone cell responses of beta-type Ti-24Nb-4Zr-8Sn alloy".SCIENTIFIC REPORTS 8(2018):-. |
入库方式: OAI收割
来源:金属研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。