英文摘要 | The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by ail electric field and deflected 180 degrees by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8 x 10(-6) For Delta m/m was achieved by using this time detector in a pilot mass measurement experiment. |
资助项目 | National Natural Science Foundation of China[10635080] ; National Natural Science Foundation of China[10221003] ; State Key Development Program of Basics Research of China[2007CB815000] ; Chinese Academy of Sciences[CXTD-J2005-1] ; Chinese Academy of Sciences[KJCX2-SWN18] |
WOS研究方向 | Physics |
语种 | 英语 |
WOS记录号 | WOS:000275495100011 |
出版者 | CHINESE PHYSICAL SOC |
资助机构 | National Natural Science Foundation of China ; State Key Development Program of Basics Research of China ; Chinese Academy of Sciences |
公开日期 | 2011-04-20 |
源URL | [http://ir.imp.cas.cn/handle/113462/8093] ![]() |
专题 | 近代物理研究所_近代物理研究所知识存储(2010之前) 近代物理研究所_实验物理中心 近代物理研究所_兰州重离子研究装置 中国科学院近代物理研究所 |
通讯作者 | Tu Xiao-Lin |
作者单位 | 1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China 2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Tu Xiao-Lin,Wang Meng,Hu Zheng-Guo,et al. Secondary electron time detector for mass measurements at CSRe[J]. CHINESE PHYSICS C,2010,34(3):363-367. |
APA | Tu Xiao-Lin.,Wang Meng.,Hu Zheng-Guo.,Xu Hu-Shan.,Guo Zhong-Yan.,...&Yue Ke.(2010).Secondary electron time detector for mass measurements at CSRe.CHINESE PHYSICS C,34(3),363-367. |
MLA | Tu Xiao-Lin,et al."Secondary electron time detector for mass measurements at CSRe".CHINESE PHYSICS C 34.3(2010):363-367. |
入库方式: OAI收割
来源:近代物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。