中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Rapid enthalpy probe

文献类型:期刊论文

作者Zhao Tai-Ze; Wang Fei; Guo Shao-Feng; Guo Wen-Kang; Xu Ping
刊名ACTA PHYSICA SINICA
出版日期2007-10-01
卷号56页码:5952-5957
关键词enthalpy probe plasma plasma diagnose
ISSN号1000-3290
英文摘要Traditional enthalpy probe system use the Mass Flux Controller (MFC) to measure the flux rate of sample gas. However, this method much depend on the composition of plasma working gas under the condition of steady state of sample gas inside the probe, so it takes much more time to measure the enthalpy of a point. In order to overcome the disadvantage of traditional probe the rapid enthalpy probe system we devised measure the molar weight of sample gas by using a known volume gas container instead of MFC, making it possible to measure the enthalpy of one point in several seconds. The accuracy of result acquired by our rapid enthalpy probe system is verified through our four different experiments.
WOS关键词PLASMA
WOS研究方向Physics
语种英语
WOS记录号WOS:000250313000066
出版者CHINESE PHYSICAL SOC
源URL[http://119.78.100.186/handle/113462/27624]  
专题中国科学院近代物理研究所
通讯作者Guo Wen-Kang
作者单位Fudan Univ, Inst Modern Phys, Shanghai 200433, Peoples R China
推荐引用方式
GB/T 7714
Zhao Tai-Ze,Wang Fei,Guo Shao-Feng,et al. Rapid enthalpy probe[J]. ACTA PHYSICA SINICA,2007,56:5952-5957.
APA Zhao Tai-Ze,Wang Fei,Guo Shao-Feng,Guo Wen-Kang,&Xu Ping.(2007).Rapid enthalpy probe.ACTA PHYSICA SINICA,56,5952-5957.
MLA Zhao Tai-Ze,et al."Rapid enthalpy probe".ACTA PHYSICA SINICA 56(2007):5952-5957.

入库方式: OAI收割

来源:近代物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。