Rapid enthalpy probe
文献类型:期刊论文
作者 | Zhao Tai-Ze; Wang Fei; Guo Shao-Feng; Guo Wen-Kang; Xu Ping |
刊名 | ACTA PHYSICA SINICA
![]() |
出版日期 | 2007-10-01 |
卷号 | 56页码:5952-5957 |
关键词 | enthalpy probe plasma plasma diagnose |
ISSN号 | 1000-3290 |
英文摘要 | Traditional enthalpy probe system use the Mass Flux Controller (MFC) to measure the flux rate of sample gas. However, this method much depend on the composition of plasma working gas under the condition of steady state of sample gas inside the probe, so it takes much more time to measure the enthalpy of a point. In order to overcome the disadvantage of traditional probe the rapid enthalpy probe system we devised measure the molar weight of sample gas by using a known volume gas container instead of MFC, making it possible to measure the enthalpy of one point in several seconds. The accuracy of result acquired by our rapid enthalpy probe system is verified through our four different experiments. |
WOS关键词 | PLASMA |
WOS研究方向 | Physics |
语种 | 英语 |
WOS记录号 | WOS:000250313000066 |
出版者 | CHINESE PHYSICAL SOC |
源URL | [http://119.78.100.186/handle/113462/27624] ![]() |
专题 | 中国科学院近代物理研究所 |
通讯作者 | Guo Wen-Kang |
作者单位 | Fudan Univ, Inst Modern Phys, Shanghai 200433, Peoples R China |
推荐引用方式 GB/T 7714 | Zhao Tai-Ze,Wang Fei,Guo Shao-Feng,et al. Rapid enthalpy probe[J]. ACTA PHYSICA SINICA,2007,56:5952-5957. |
APA | Zhao Tai-Ze,Wang Fei,Guo Shao-Feng,Guo Wen-Kang,&Xu Ping.(2007).Rapid enthalpy probe.ACTA PHYSICA SINICA,56,5952-5957. |
MLA | Zhao Tai-Ze,et al."Rapid enthalpy probe".ACTA PHYSICA SINICA 56(2007):5952-5957. |