Self-aspiration sampling extractive electrospray ionization mass spectrometry (EESI-MS) for high-throughput analysis of liquid samples
文献类型:期刊论文
作者 | Jia, Bin1,2; Zhang, Shuai3; Yan, Ling1,2; He, Shoubo4; Liu, Baohong1,2; Shen, Huali1,2; Yang, Pengyuan1,2 |
刊名 | RAPID COMMUNICATIONS IN MASS SPECTROMETRY
![]() |
出版日期 | 2016-08-01 |
卷号 | 30页码:56-61 |
ISSN号 | 0951-4198 |
DOI | 10.1002/rcm.7616 |
英文摘要 | RATIONALE: Extractive electrospray ionization mass spectrometry (EESI-MS) was invented as a typical ambient mass spectrometry method (AMS) and has been used for analyzing complex liquid samples. Here, we designed a Venturi effect-based self-aspiration sampling device and applied it to the EESI-MS for high-throughput analysis of liquid sample. METHODS: A special concentric nebulizer was designed and employed to produce a suction force for the direct aspiration of liquid samples, followed by ionization and detection. This sample aspiration process was explained and optimized using computational fluid dynamics (CFD) analysis. Experiment data were recorded to exhibit the sensitivity, memory effect, inter-day reproducibility, throughput, and applicability of the self-aspiration sampling EESI-MS. RESULTS: The limit of detection (LOD) of this method was determined as 4.5 x 10(-10) g/mL (S/N = 3) for caffeine, and the sample throughput and relative standard deviation (RSD) for full scan mode can reach 0.67 samples/s and 4.76%, respectively. Even for MS/MS mode, the frequency can still be kept at 0.4 samples/s (RSD = 4.71%). Inter-day RSD examined in 1 week was below 10% for the signal of characteristic fragment ions of reserpine. Moreover, based on this method, the amount of caffeine in instant coffee was determined as 4.7%. This device was also proven to be suitable for the protein/peptide analysis. CONCLUSIONS: These experiment results, especially the amazing results on sample throughput and inter-day RSD, suggest that we provide a valuable device which can be used for the direct high-throughput qualitative/quantitative mass spectrometry analysis of real liquid samples in ambient. Copyright (C) 2016 John Wiley & Sons, Ltd. |
WOS关键词 | REAL-TIME ; RAPID CHARACTERIZATION ; AMBIENT CONDITIONS |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry ; Spectroscopy |
语种 | 英语 |
WOS记录号 | WOS:000382975400012 |
出版者 | WILEY-BLACKWELL |
源URL | [http://119.78.100.186/handle/113462/43214] ![]() |
专题 | 中国科学院近代物理研究所 |
通讯作者 | Shen, Huali; Yang, Pengyuan |
作者单位 | 1.Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China 2.Fudan Univ, Inst Biomed Sci, Shanghai 200433, Peoples R China 3.Fudan Univ, Sch Basic Med Sci, Dept Anat Histol & Embryol, Shanghai 200032, Peoples R China 4.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China |
推荐引用方式 GB/T 7714 | Jia, Bin,Zhang, Shuai,Yan, Ling,et al. Self-aspiration sampling extractive electrospray ionization mass spectrometry (EESI-MS) for high-throughput analysis of liquid samples[J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY,2016,30:56-61. |
APA | Jia, Bin.,Zhang, Shuai.,Yan, Ling.,He, Shoubo.,Liu, Baohong.,...&Yang, Pengyuan.(2016).Self-aspiration sampling extractive electrospray ionization mass spectrometry (EESI-MS) for high-throughput analysis of liquid samples.RAPID COMMUNICATIONS IN MASS SPECTROMETRY,30,56-61. |
MLA | Jia, Bin,et al."Self-aspiration sampling extractive electrospray ionization mass spectrometry (EESI-MS) for high-throughput analysis of liquid samples".RAPID COMMUNICATIONS IN MASS SPECTROMETRY 30(2016):56-61. |
入库方式: OAI收割