文献类型:期刊论文
作者 | Li, Min1,2![]() |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
![]() |
出版日期 | 2015-03-11 |
卷号 | 776页码:21-26 |
关键词 | HIMM Multi-strip ionization chamber NI CompactRIO Producer-consumer pattern Data acquisition system |
ISSN号 | 0168-9002 |
DOI | 10.1016/j.nima.2014.12.021 |
英文摘要 | Heavy Ion Medical Machine (HIMM) is a carbon ion cancer treatment facility which is being built by the Institute of Modern Physics (IMP) in China. In this facility, transverse profile and intensity of the beam at the treatment terminals will be measured by the multi strip ionization chamber. In order to fulfill the requirement of the beam position feedback to accomplish the beam automatic commissioning, less than 1 ms reaction time of the Data Acquisition (DAQ) of this detector must be achieved. Therefore, the control system and software framework for DAQ have been redesigned and developed with National Instruments Compact Reconfigurable Input/Output (CompactRIO) instead of PXI 6133. The software is Labview-based and developed following the producer-consumer pattern with message mechanism and queue technology. The newly designed control system has been tested with carbon beam at the Heavy Ion Research Facility at Lanzhou-Cooler Storage Ring (HIRFL-CSR) and it has provided one single beam profile measurement in less than 1 ms with 1 mm beam position resolution. The fast reaction time and high precision data processing during the beam test have verified the usability and maintainability of the software framework. Furthermore, such software architecture is easy-fitting to applications with different detectors such as wire scanner detector. (C) 2014 Elsevier B.V. All rights reserved. |
WOS关键词 | THERAPY |
WOS研究方向 | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics |
语种 | 英语 |
WOS记录号 | WOS:000349468500004 |
出版者 | ELSEVIER SCIENCE BV |
源URL | [http://119.78.100.186/handle/113462/56767] ![]() |
专题 | 中国科学院近代物理研究所 |
通讯作者 | Li, Min |
作者单位 | 1.Chinese Acad Sci, IMP, Lanzhou 730000, Peoples R China 2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Li, Min,Yuan, Y. J.,Mao, R. S.,et al. The control system of the multi-strip ionization chamber for the HIMM[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2015,776:21-26. |
APA | Li, Min.,Yuan, Y. J..,Mao, R. S..,Xu, Z. G..,Li, Peng.,...&Zhang, Nong.(2015).The control system of the multi-strip ionization chamber for the HIMM.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,776,21-26. |
MLA | Li, Min,et al."The control system of the multi-strip ionization chamber for the HIMM".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 776(2015):21-26. |