Study on the Real-Time Lossless Data Compression Method Used in the Readout System for Micropattern Gas Detector
文献类型:期刊论文
作者 | Shen, Zhongtao1,2; Li, Cheng1,2; Wang, Shuwen1,2; Feng, Changqing1,2; Liu, Shubin1,2 |
刊名 | IEEE TRANSACTIONS ON NUCLEAR SCIENCE |
出版日期 | 2019-08-01 |
卷号 | 66期号:8页码:2017-2021 |
ISSN号 | 0018-9499 |
关键词 | Data compression micropattern gas detector (MPGD) |
DOI | 10.1109/TNS.2019.2925840 |
通讯作者 | Liu, Shubin(liushb@ustc.edu.cn) |
英文摘要 | Nowadays, the data compression technique is fully developed and widely used in many fields, such as communication, multi-media, image processing, and so on. In large physics experiments, especially the ones with micropattern gas detectors (MPGDs), there are always large numbers of readout channels and many data to be transferred. However, the data compression technique is seldom applied in this field. In this paper, a real-time lossless data compression method, which can reduce the data transmission bandwidth while keeping all information of data is proposed and successfully implemented in a general-purpose MPGD readout system. The compression method discussed in this paper mainly consists of two steps: The first step is to preprocess the data according to the signal characteristics and the second step is to compress the preprocessed data using a common lossless compression algorithm. In addition, the whole compression method is implemented in the field-programmable gate array (FPGA) and can run in real time. The compression method is validated with two different signals and the compression ratios reach 43% and 30%, respectively. |
资助项目 | State Key Laboratory of Particle Detection and Electronics[SKLPDE_ZZ_201817] |
WOS研究方向 | Engineering ; Nuclear Science & Technology |
语种 | 英语 |
出版者 | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
WOS记录号 | WOS:000481936800014 |
资助机构 | State Key Laboratory of Particle Detection and Electronics |
源URL | [http://119.78.100.186/handle/113462/132894] |
专题 | 中国科学院近代物理研究所 |
通讯作者 | Liu, Shubin |
作者单位 | 1.Univ Sci & Technol China, State Key Lab Particle Detect & Elect, Hefei 230026, Anhui, Peoples R China 2.Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Anhui, Peoples R China |
推荐引用方式 GB/T 7714 | Shen, Zhongtao,Li, Cheng,Wang, Shuwen,et al. Study on the Real-Time Lossless Data Compression Method Used in the Readout System for Micropattern Gas Detector[J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE,2019,66(8):2017-2021. |
APA | Shen, Zhongtao,Li, Cheng,Wang, Shuwen,Feng, Changqing,&Liu, Shubin.(2019).Study on the Real-Time Lossless Data Compression Method Used in the Readout System for Micropattern Gas Detector.IEEE TRANSACTIONS ON NUCLEAR SCIENCE,66(8),2017-2021. |
MLA | Shen, Zhongtao,et al."Study on the Real-Time Lossless Data Compression Method Used in the Readout System for Micropattern Gas Detector".IEEE TRANSACTIONS ON NUCLEAR SCIENCE 66.8(2019):2017-2021. |
入库方式: OAI收割
来源:近代物理研究所
浏览0
下载0
收藏0
其他版本