中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Nonlinear response of phosphor screen used in velocity map imaging spectrometry

文献类型:期刊论文

作者Ma, Xin-Wen2; Li, Yu-Fan1,2; Zhao, Dong-Mei2; Zhou, Wen-Chang1,2; Qian, Dong-Bin2; Yang, Jie2; Zhang, Shao-Feng2; Zhu, Xiao-Long2
刊名INTERNATIONAL JOURNAL OF MASS SPECTROMETRY
出版日期2019-08-01
卷号442页码:23-28
关键词Velocity map imaging Photoion imaging Photoelectron imaging Linearity of detector
ISSN号1387-3806
DOI10.1016/j.ijms.2019.04.007
通讯作者Qian, Dong-Bin(qiandb@impcas.ac.cn) ; Yang, Jie(jie.yang@impcas.ac.cn)
英文摘要We present an approach to experimentally investigate the nonlinear response of phosphor screen (PS) module applied in velocity-map-imaging spectrometry under the condition of microchannel plate (MCP) module working in an appropriate amplifier voltage to ensure a constant unsaturation gain. Our approach, taking the Photek's VID240 detector system as an example, is based on the measurements of the position spectra of Rb-87(+) photoion pulses with well-determined numbers of ions and duration times at various voltage differences (U-f) between MCP and PS modules. The measured spectra allow us to obtain the relationship between the two-dimensional distribution of luminescence (the luminescence intensity in the kth pixel) and the total number of ions in one pulse at a given Uf value. The obtained relationship leads to the luminescence efficiency and the acceptable limit of input ion flux density (the maximal number of ions arriving at MCP per unit time per unit area to avoid the nonlinear response) for a particular PS to be determined. (C) 2019 Elsevier B.V. All rights reserved.
WOS关键词DETECTION EFFICIENCIES ; MICROCHANNEL ; DETECTOR ; ENERGY ; ELECTRONS ; IONS
资助项目National Key RD Program[2017YFA0402300] ; NSFC program[U1232122] ; NSFC program[U1632143]
WOS研究方向Physics ; Spectroscopy
语种英语
WOS记录号WOS:000472151800004
出版者ELSEVIER SCIENCE BV
资助机构National Key RD Program ; NSFC program
源URL[http://119.78.100.186/handle/113462/133146]  
专题中国科学院近代物理研究所
通讯作者Qian, Dong-Bin; Yang, Jie
作者单位1.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
2.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Gansu, Peoples R China
推荐引用方式
GB/T 7714
Ma, Xin-Wen,Li, Yu-Fan,Zhao, Dong-Mei,et al. Nonlinear response of phosphor screen used in velocity map imaging spectrometry[J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY,2019,442:23-28.
APA Ma, Xin-Wen.,Li, Yu-Fan.,Zhao, Dong-Mei.,Zhou, Wen-Chang.,Qian, Dong-Bin.,...&Zhu, Xiao-Long.(2019).Nonlinear response of phosphor screen used in velocity map imaging spectrometry.INTERNATIONAL JOURNAL OF MASS SPECTROMETRY,442,23-28.
MLA Ma, Xin-Wen,et al."Nonlinear response of phosphor screen used in velocity map imaging spectrometry".INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 442(2019):23-28.

入库方式: OAI收割

来源:近代物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。