Improvement of charge resolution for radioactive heavy ions at relativistic energies using a hybrid detector system
文献类型:期刊论文
作者 | Sun, Z. Y.3; Sun, Y. Z.3; Shen, D. P.1; Lu, C. G.3; Liu, Z.3![]() |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
![]() |
出版日期 | 2019-06-21 |
卷号 | 930页码:95-99 |
关键词 | Charge resolution Energy loss determination Radioactive ion beam Particle identification |
ISSN号 | 0168-9002 |
DOI | 10.1016/j.nima.2019.03.063 |
通讯作者 | Sun, B. H.(bhsun@buaa.edu.cn) |
英文摘要 | In typical nuclear physics experiments with radioactive ion beams (RIBs) selected by the in-flight separation technique, Si detectors or ionization chambers are usually equipped for the charge determination of RIBs. The obtained charge resolution relies on the performance of these detectors for energy loss determination, and this affects the particle identification capability of RIBs. We present an approach on improving the resolution of charge measurement for heavy ions by using the abundant energy loss information from different types of existing detectors along the beam line. Without altering the beam line and detectors, this approach can improve the charge resolution by more than 12% relative to the multiple sampling ionization chamber of the best resolution. |
资助项目 | National Key R&D program of China[2016YFA0400504] ; National Natural Science Foundation of China[U1832211] ; National Natural Science Foundation of China[11475014] ; National Natural Science Foundation of China[U1867210] |
WOS研究方向 | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics |
语种 | 英语 |
WOS记录号 | WOS:000464991900012 |
出版者 | ELSEVIER SCIENCE BV |
资助机构 | National Key R&D program of China ; National Natural Science Foundation of China |
源URL | [http://119.78.100.186/handle/113462/133713] ![]() |
专题 | 中国科学院近代物理研究所 |
通讯作者 | Sun, B. H. |
作者单位 | 1.Beihang Univ, Sch Phys & Nucl Energy Engn, Beijing 100191, Peoples R China 2.Beihang Univ, Beijing Adv Innovat Ctr Big Data Based Precis Med, Beijing 100083, Peoples R China 3.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Gansu, Peoples R China 4.Osaka Univ, Res Ctr Nucl Phys, Osaka 5670047, Japan 5.Vietnam Acad Sci & Technol, Inst Phys, Hanoi 10000, Vietnam |
推荐引用方式 GB/T 7714 | Sun, Z. Y.,Sun, Y. Z.,Shen, D. P.,et al. Improvement of charge resolution for radioactive heavy ions at relativistic energies using a hybrid detector system[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2019,930:95-99. |
APA | Sun, Z. Y..,Sun, Y. Z..,Shen, D. P..,Lu, C. G..,Liu, Z..,...&Tanihata, I.(2019).Improvement of charge resolution for radioactive heavy ions at relativistic energies using a hybrid detector system.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,930,95-99. |