英文摘要 | The article presents the study and new development at SFC, the HIRFL injector cyclotron. It includes the new central region, the new buncher system and the new axial injection line. It introduces the half-frequency bunching method to increase the longitudinal matching efficiency between the injector and the main cyclotron and the special treatment for the space charge effect by using two injection parameters. The constant orbit acceleration with small variation is introduced to solve the contradiction of the lower RF voltage and less turn number. Two on-line ECR ion sources, high charge state resolving power and other improvements on the injection line have been included. |
WOS研究方向 | Physics |
语种 | 英语 |
WOS记录号 | WOS:000166175000015 |
出版者 | SCIENCE PRESS |
公开日期 | 2010-10-29 |
源URL | [http://ir.imp.cas.cn/handle/113462/1405] ![]() |
专题 | 近代物理研究所_近代物理研究所知识存储(2010之前) |
通讯作者 | Tang, JY |
作者单位 | Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China |
推荐引用方式 GB/T 7714 | Tang, JY,Jiang, JZ,Li, ZH,et al. Study and design of the axial injection system at SFC[J]. HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION,2000,24(12):1173-1178. |
APA | Tang, JY,Jiang, JZ,Li, ZH,Xu, XY,Wang, YF,&Yin, QM.(2000).Study and design of the axial injection system at SFC.HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION,24(12),1173-1178. |
MLA | Tang, JY,et al."Study and design of the axial injection system at SFC".HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION 24.12(2000):1173-1178. |
入库方式: OAI收割
来源:近代物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。