Development of multi-channel gated integrator and PXI-DAQ system for nuclear detector arrays
文献类型:期刊论文
作者 | Ma, Jun-Bing1; Kong, Jie1,2![]() ![]() |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
![]() |
出版日期 | 2010-10-01 |
卷号 | 622期号:1页码:215-218 |
关键词 | Multi-channel gated integrator Data acquisition system PXI LabWindows/CVI |
ISSN号 | 0168-9002 |
DOI | 10.1016/j.nima.2010.07.030 |
英文摘要 | A multi-channel gated integrator and PXI based data acquisition system have been developed for nuclear detector arrays with hundreds of detector units. The multi-channel gated integrator can be controlled by a programmable Cl controller. The PXI-DAQ system consists of NI PXI-1033 chassis with several PXI-DAQ cards. The system software has a user-friendly GUI which is written in C language using LabWindows/CVI under Windows XP operating system. The performance of the PXI-DAQ system is very reliable and capable of handling event rate up to 40 kHz. (C) 2010 Elsevier B.V. All rights reserved. |
WOS关键词 | DATA-ACQUISITION SYSTEM ; RIBLL |
资助项目 | National Natural Science Foundation of China[10675153] ; National Natural Science Foundation of China[10735060] ; CAS[KJCX2-YIN-N27] ; Chinese Academy of Sciences |
WOS研究方向 | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics ; Spectroscopy |
语种 | 英语 |
WOS记录号 | WOS:000282530300031 |
出版者 | ELSEVIER SCIENCE BV |
资助机构 | National Natural Science Foundation of China ; CAS ; Chinese Academy of Sciences |
公开日期 | 2011-04-20 |
源URL | [http://ir.imp.cas.cn/handle/113462/8005] ![]() |
专题 | 近代物理研究所_近代物理研究所知识存储(2010之前) |
通讯作者 | Chen, Zhi-Qiang |
作者单位 | 1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China 2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Ma, Jun-Bing,Kong, Jie,Su, Hong,et al. Development of multi-channel gated integrator and PXI-DAQ system for nuclear detector arrays[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2010,622(1):215-218. |
APA | Ma, Jun-Bing.,Kong, Jie.,Su, Hong.,Chen, Zhi-Qiang.,Dong, Cheng-Fu.,...&Ye, Rui-Ping.(2010).Development of multi-channel gated integrator and PXI-DAQ system for nuclear detector arrays.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,622(1),215-218. |
MLA | Ma, Jun-Bing,et al."Development of multi-channel gated integrator and PXI-DAQ system for nuclear detector arrays".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 622.1(2010):215-218. |
入库方式: OAI收割