VACUUM SYSTEM OF HIRFL’S CYCLOTRONS

文献类型:研究报告

作者X.T. Yang# ; J.H.Zhang ; Z.M.You ; J.Meng and Vacuum group of IMP
完成日期2010-09-10
关键词Hirfl Sector Focus Cyclotron Separate Sector Cyclotron
英文摘要HIRFL has 2 cyclotrons: a sector focus cyclotron (SFC)
and a separate sector cyclotron (SSC). SFC was built in
1957. In the past 50 years, the vacuum system of SFC has
been upgraded for three times. The vacuum chamber was
redesigned to double-deck at the third upgrade. The
working pressure in beam chamber was improved from
10-6mbar to 10-8mbar. SFC has delivered Pb, Bi and U
beams in the past few years since the last upgrading of its
vacuum chamber. SSC began to operate in 1987. The
vacuum chamber of SSC has a volume of 100m3. 8
cryopumps keep the pressure from 5×10-7mbar to 8×10-
8mbar depending on the used pump numbers (2~8). In the
past 20 years, because of the contamination of oil vapour
and leaks occurred in some components inside the SSC
vacuum chamber, the vacuum condition has worsened
than the beginning. It is a big problem to accelerate the
heavier ions. The upgrade for the SSC vacuum system
will be an urgent task for us. The rough pumping systems
of both SFC and SSC have been rebuilt recently. As a
result, the oil vapour in two cyclotrons will be eliminated
and the vacuum condition of them will be improved.
A new small cyclotron will be built in HIRFL as an
injector of the Heavy Ion Therapy Facility in Lanzhou
(HITFiL). The brief introduction of the vacuum system
design is given in the paper.