DESIGN OF IBA CYCLONE®11 CYCLOTRON MAGNET
文献类型:会议论文
作者 | V. Nuttens ; M. Abs ; W. Kleeven ; B. Nactergal ; D. Neuveglise ; T. Servais ; S. Zaremba |
出版日期 | 2010-09-10 |
会议日期 | 2010-09-06 |
会议地点 | 兰州 |
英文摘要 | The development of a new Cyclone®11 11MeV Hcyclotron is in progress at IBA. Such machine is designed for the production of radionuclides for nuclear medicine. This cyclotron is based on the existing Cyclone®10 that has been boosted to more than 11 MeV with as minor as possible change to the Cyclone®10 geometry. At first, the magnetic field has been raised by a small reduction of the valley depth. Additionally, the main coil current has been increased. Pole edge milling has been used to obtain the isochronous magnetic field shape. Beam optics in the magnet is excellent. Extraction is ensured by means of stripper foils mounted on carousels located at different azimuths allowing installation up to eight targets and dual beam extraction. |
资助机构 | IMP;Chinese Academy of Sciences |
会议录 | The 19th International Conference on Cyclotrons and their Applications, CYCLOTRONS'22
![]() |
语种 | 英语 |
URL标识 | 查看原文 |
源URL | [http://ir.imp.cas.cn/handle/113462/8543] ![]() |
专题 | 近代物理研究所_近代物理研究所知识存储(2010之前) |
推荐引用方式 GB/T 7714 | V. Nuttens,M. Abs,W. Kleeven,et al. DESIGN OF IBA CYCLONE®11 CYCLOTRON MAGNET[C]. 见:. 兰州. 2010-09-06. |
入库方式: OAI收割
来源:近代物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。