CONSISTENCY IN MEASUREMENT OF BEAM PHASE AND INTENSITY USING LOCK-IN AMPLIFIER AND OSCILLOSCOPE SYSTEMS
文献类型:会议论文
作者 | R. Koyama ; , M. Fujimaki ; N. Fukunishi ; A. Goto ; M. Hemmi ; M. Kase1 ; N. Sakamoto ; K. Suda ; T. Watanabe ; K. Yamada ; O. Kamigaito |
出版日期 | 2010-09-10 |
会议日期 | 2010-09-06 |
会议地点 | 兰州 |
英文摘要 | The phase probes (PPs) are installed in all cyclotrons and beam transport lines of RIBF, and the beam-bunch signals that are detected nondestructively by these PPs are used for tuning of isochronism of cyclotrons and for monitoring the beam phase and beam intensity. We mainly use a newly developed system that incorporates a lock-in amplifier (LIA) for those tuning and monitoring; however, a conventional measurement method using an oscilloscope (OSC) system is also used. In this study, we investigated the consistency in the measurements carried out using LIA and OSC systems by FFT analyzing the observed data. Additionally, we investigated the measurement accuracy of LIA and OSC |
资助机构 | IMP;Chinese Academy of Sciences |
会议录 | The 19th International Conference on Cyclotrons and their Applications, CYCLOTRONS'39
![]() |
语种 | 英语 |
URL标识 | 查看原文 |
源URL | [http://ir.imp.cas.cn/handle/113462/8577] ![]() |
专题 | 近代物理研究所_近代物理研究所知识存储(2010之前) |
推荐引用方式 GB/T 7714 | R. Koyama,, M. Fujimaki,N. Fukunishi,et al. CONSISTENCY IN MEASUREMENT OF BEAM PHASE AND INTENSITY USING LOCK-IN AMPLIFIER AND OSCILLOSCOPE SYSTEMS[C]. 见:. 兰州. 2010-09-06. |