Temperature dependence of the plastic scintillator detector for DAMPE
文献类型:期刊论文
作者 | Chen, Jun-Ling3; Yue, Ke3![]() ![]() ![]() ![]() ![]() ![]() ![]() |
刊名 | CHINESE PHYSICS C
![]() |
出版日期 | 2017 |
卷号 | 41页码:6 |
关键词 | DAMPE PSD PMT temperature dependence correction |
ISSN号 | 1674-1137 |
DOI | 10.1088/1674-1137/41/1/016001 |
英文摘要 | The Plastic Scintillator Detector (PSD) is one of the main sub-detectors in the DArk Matter Particle Explorer (DAMPE) project. It will be operated over a large temperature range from -10 to 30 degrees C, so the temperature effect of the whole detection system should be studied in detail. The temperature dependence of the PSD system is mainly contributed by the three parts: the plastic scintillator bar, the photomultiplier tube (PMT), and the Front End Electronics (FEE). These three parts have been studied in detail and the contribution of each part has been obtained and discussed. The temperature coefficient of the PMT is -0.320(+/- 0.033)%/degrees C, and the coefficient of the plastic scintillator bar is -0.036(+/- 0.038)%/degrees C. This result means that after subtracting the FEE pedestal, the variation of the signal amplitude of the PMT-scintillator system due to temperature mainly comes from the PMT, and the plastic scintillator bar is not sensitive to temperature over the operating range. Since the temperature effect cannot be ignored, the temperature dependence of the whole PSD has been also studied and a correction has been made to minimize this effect. The correction result shows that the effect of temperature on the signal amplitude of the PSD system can be suppressed. |
资助项目 | Strategic Priority Research Program on Space Science of the Chinese Academy of Sciences[XDA04040202-3] ; Youth Innovation Promotion Association, CAS |
WOS研究方向 | Physics |
语种 | 英语 |
WOS记录号 | WOS:000393254200015 |
出版者 | CHINESE PHYSICAL SOC |
资助机构 | Strategic Priority Research Program on Space Science of the Chinese Academy of Sciences ; Youth Innovation Promotion Association, CAS |
源URL | [http://119.78.100.186/handle/113462/44282] ![]() |
专题 | 近代物理研究所_实验物理中心 |
通讯作者 | Wang, Zhao-Min |
作者单位 | 1.Univ Chinese Acad Sci, Beijing 100049, Peoples R China 2.Univ Sci & Technol China, Hefei 230026, Peoples R China 3.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China |
推荐引用方式 GB/T 7714 | Chen, Jun-Ling,Yue, Ke,Yan, Duo,et al. Temperature dependence of the plastic scintillator detector for DAMPE[J]. CHINESE PHYSICS C,2017,41:6. |