Design and RF test of MEBT buncher cavities for C-ADS Injector II at IMP

文献类型:期刊论文

作者Niu, Haihua1; Xia, Jiawen1; Zhao, Hongwei1; Zhang, Peng1; Chang, Wei1; Zhang, Shengxue1; Wang, Jing3; Yuan, Chenzhang1; Zhang, Shenghu1; He, Yuan1
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
出版日期2015-11-01
卷号799页码:44-49
关键词Buncher Cavity Mebt Rf Design Mechanical And Thermal Analysis High Power Test Ads
ISSN号0168-9002
DOI10.1016/j.nima.2015.07.047
英文摘要

To match the beam from the Radio Frequency Quadrupole (RFQ) accelerator to the Superconducting Half-wave Resonator (HWR) Linac, two room temperature (RT) double-gap Quarter-wave Resonator (QWR) bundlers are designed to be located in the Medium Energy Beam Transport Line (MEBT) for the C-ADS Injector II at IMP. Both cavities work at 162.5 MHz, with beta=0.067 and a beam aperture diameter of 40 mm. The effective voltage of these two cavities needs to reach 135 kV in Continuous Wave (CW) mode. In this paper, the RF design and thermal analysis of the cavities will be presented, along with the tuners and coupler consideration. The measured frequencies, R-sh/Q(0), Q(0) and voltage of the cavities agree well with the simulation result. Details of the RI test results including the full power tests of the cavities will be shown. (C) 2015 Elsevier B.V. All rights reserved.

资助项目National Natural Science Foundation of China[91026004]
WOS研究方向Instruments & Instrumentation ; Nuclear Science & Technology ; Physics ; Spectroscopy
语种英语
WOS记录号WOS:000361877300007
出版者ELSEVIER SCIENCE BV
资助机构National Natural Science Foundation of China
源URL[http://ir.impcas.ac.cn/handle/113462/22697]  
专题近代物理研究所_直线加速器中心
近代物理研究所_兰州重离子研究装置
作者单位1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
3.Lanzhou Univ Technol, Lanzhou 730050, Peoples R China
推荐引用方式
GB/T 7714
Niu, Haihua,Xia, Jiawen,Zhao, Hongwei,et al. Design and RF test of MEBT buncher cavities for C-ADS Injector II at IMP[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2015,799:44-49.
APA Niu, Haihua.,Xia, Jiawen.,Zhao, Hongwei.,Zhang, Peng.,Chang, Wei.,...&Huang, Shichun.(2015).Design and RF test of MEBT buncher cavities for C-ADS Injector II at IMP.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,799,44-49.
MLA Niu, Haihua,et al."Design and RF test of MEBT buncher cavities for C-ADS Injector II at IMP".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 799(2015):44-49.

入库方式: OAI收割

来源:近代物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。