A new microphonics measurement method for superconducting RF cavities
文献类型:期刊论文
作者 | Gao, Z4; He, Y4; Chang, W4; Powers, T4; Yue, WM4; Zhu, ZL4; Chen, Q4; Gao, Z (reprint author), Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China. |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
![]() |
出版日期 | 2014 |
卷号 | 767页码:212-217 |
关键词 | Microphonics Superconducting cavity FPGA I/Q |
ISSN号 | 0168-9002 |
DOI | 10.1016/j.nima.2014.08.030 |
英文摘要 | Mechanical vibrations of the superconducting cavity, also known as microphonics, cause shifts in the resonant frequency of the cavity. In addition to requiring additional RF power, these frequency shifts can contribute to errors in the closed loop phase and amplitude regulation. In order to better understand these effects, a new microphonics measurement method was developed, and the method was successfully used to measure microphonics on the half wave superconducting cavity when it was operated in a production style cryostat. The test cryostat held a single beta=0.1 half wave cavity which was operated at 162.5 MHz Yue et al. (2013) and Wang et al. (2013) [1,2]. It is the first time that the National Instruments PXle-5641R intermediate frequency transceiver has been used for microphonics measurements in superconducting cavities. The new microphonics measurement method and results will be shown and analyzed in this paper. (C) 2014 Elsevier B.V. All rights reserved. |
资助项目 | National Nature Science Foundation of China[91026001] |
WOS研究方向 | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics |
语种 | 英语 |
WOS记录号 | WOS:000344994600028 |
出版者 | ELSEVIER SCIENCE BV |
源URL | [http://ir.impcas.ac.cn/handle/113462/22718] ![]() |
专题 | 近代物理研究所_直线加速器中心 |
通讯作者 | Gao, Z (reprint author), Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China. |
作者单位 | 1.Chang, Wei 2.[Powers, Tom] Thomas Jefferson Natl Accelerator Facil, Newport News, VA 23606 USA 3.Chen, Qi] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China 4.[Gao, Zheng 5.He, Yuan 6.Chang, Wei 7.Yue, Wei-ming 8.Zhu, Zheng-long 9.Chen, Qi] Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China 10.[Gao, Zheng |
推荐引用方式 GB/T 7714 | Gao, Z,He, Y,Chang, W,et al. A new microphonics measurement method for superconducting RF cavities[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2014,767:212-217. |