Transmission efficiency improvement of the injector line of SFC by particle beam decorrelation

文献类型:期刊论文

作者Zhang Wen-Hui1; Yuan You-Jin1; Feng Yu-Chen1; Sun Liang-Ting1; Fang Xing1; Lu Wang1; Cao Yun1; Yang Yao1,2; Zhao Hong-Wei1; Zhang Xue-Zhen1
刊名NUCLEAR SCIENCE AND TECHNIQUES
出版日期2015-12-01
卷号26页码:6
关键词Electron cyclotron resonance Emittance Transverse Coupling
ISSN号1001-8042
英文摘要The operation of the HIRFL accelerator has shown that the beam transmission efficiency of the sector focusing cyclotron (SFC) injector line is rather poor. Beam simulations have been performed to investigate the possible causes for this low transmission. It is predicted that the property of transversal coupling of the ion beam from electron cyclotron resonance (ECR) ion source can be an important factor to degrade the beam quality by increasing the beam emittance, resulting in a serious particle loss. An improved operation scheme for the SECRAL associated line has been proposed, and the corresponding experiment was carried out. This paper presents the test results.
资助项目National Basic Research Program of China[2014CB845500] ; 100 Talents Program of the CAS[Y214160BR0] ; National Nature Science Foundation of China[11221064]
WOS研究方向Nuclear Science & Technology ; Physics
语种英语
WOS记录号WOS:000368964600006
出版者ELSEVIER SCIENCE BV
资助机构National Basic Research Program of China ; 100 Talents Program of the CAS ; National Nature Science Foundation of China
源URL[http://ir.impcas.ac.cn/handle/113462/23559]  
专题近代物理研究所_兰州重离子研究装置
通讯作者Yang Yao
作者单位1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Zhang Wen-Hui,Yuan You-Jin,Feng Yu-Chen,et al. Transmission efficiency improvement of the injector line of SFC by particle beam decorrelation[J]. NUCLEAR SCIENCE AND TECHNIQUES,2015,26:6.
APA Zhang Wen-Hui.,Yuan You-Jin.,Feng Yu-Chen.,Sun Liang-Ting.,Fang Xing.,...&Zhang Xue-Zhen.(2015).Transmission efficiency improvement of the injector line of SFC by particle beam decorrelation.NUCLEAR SCIENCE AND TECHNIQUES,26,6.
MLA Zhang Wen-Hui,et al."Transmission efficiency improvement of the injector line of SFC by particle beam decorrelation".NUCLEAR SCIENCE AND TECHNIQUES 26(2015):6.

入库方式: OAI收割

来源:近代物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。