Sawtooth-wave prebuncher with dual-gaps in Linac injector for HIRFL-SSC
文献类型:期刊论文
作者 | Zhang, Xiaohu2; Yuan, Youjin2![]() ![]() ![]() ![]() |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
![]() |
出版日期 | 2018-01-21 |
卷号 | 879页码:39-46 |
关键词 | Longitudinal Capture Efficiency Longitudinal Emittance Multi-harmonics Buncher Dual-gaps Multi-harmonics Synthetic Technology |
ISSN号 | 0168-9002 |
DOI | 10.1016/j.nima.2017.09.042 |
英文摘要 | An RFQ structure is normally composed of radial matcher, shaper, gentle buncher and accelerator section with changing cell geometry. Bunching is started in the shaper, and adiabatic bunching is done in gentle buncher section. The beam preforms from DC beam to bunch beam through the RFQ and the longitudinal emittance for the ions linacs is defined initially in the RFQ, in which the beam bunch has been shaped. In the present SSC-Linac injector, an RFQ has been designed to accelerate the continuous beam from 3.728 keV/u to 143 keV/u. The heavy ions beam is injected into the SSC (Separated Sector Cyclotron) with the kinetic energy of 1.025 MeV/u after four IH DTLs. The rf frequency of the SSC is 13.417 MHz, and the frequency of the heavy ions RFQ is set to four times of the rf frequency of the SSC. In order to increase the longitudinal capture efficiency of the SSC and suppress the longitudinal emittance at the exit of RFQ, an external MHB (Multi-Harmonics Buncher) is proposed in front of the RFQ. The fundamental frequency of the MHB is the same as the rf frequency of the cyclotron. The scheme of dual-gaps prebuncher with the sawtooth waveform is firstly carried out through multi-harmonics synthetic technology. The multi-particle beam dynamic simulations of the MHB have been done by the BEAMPATH code. (C) 2017 Published by Elsevier B.V. |
WOS关键词 | Design ; Csr ; Rfq |
WOS研究方向 | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics |
语种 | 英语 |
WOS记录号 | WOS:000416483900007 |
出版者 | ELSEVIER SCIENCE BV |
源URL | [http://119.78.100.186/handle/113462/46081] ![]() |
专题 | 近代物理研究所_兰州重离子研究装置 |
作者单位 | 1.Univ Chinese Acad Sci, Beijing 100049, Peoples R China 2.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Gansu, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, Xiaohu,Yuan, Youjin,Xia, Jiawen,et al. Sawtooth-wave prebuncher with dual-gaps in Linac injector for HIRFL-SSC[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2018,879:39-46. |
APA | Zhang, Xiaohu.,Yuan, Youjin.,Xia, Jiawen.,Yin, Xuejun.,Jin, Peng.,...&Wang, Kedong.(2018).Sawtooth-wave prebuncher with dual-gaps in Linac injector for HIRFL-SSC.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,879,39-46. |
MLA | Zhang, Xiaohu,et al."Sawtooth-wave prebuncher with dual-gaps in Linac injector for HIRFL-SSC".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 879(2018):39-46. |