中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Centrifuge microextraction coupled with sweeping-MEKC to analyze trace steroid hormones in urine samples

文献类型:期刊论文

作者Fang, Huaifang1; Yang, Fangxing2; Sun, Junling1; Tian, Yun1; Zeng, Zhaorui1; Xu, Ying2
刊名TALANTA
出版日期2011-09-30
卷号85期号:4页码:2148-2153
关键词Centrifuge microextraction Sweeping Micellar electrokinetic chromatography Steroid hormone
ISSN号0039-9140
通讯作者Zeng, ZR (reprint author), Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China ; zrzeng@whu.edu.cn
中文摘要A novel method that combines two concentration techniques, off-line centrifuge microextraction (CME) and on-line sweeping, is used to determine trace steroids in urine by micellar electrokinetic chromatography (MEKC). The CME-sweeping-MEKC is a promising technique, which has a variety of merits such as high sensitivity, rapid operation, minimal cost, and high sample throughput capability. Using CME-sweeping, over a 500-fold increase in sensitivity could be obtained as compared with the normal hydrodynamic injection without sample stacking. The linear range was 0.05-1 mu g mL(-1) with the square of the correlation coefficients ranging from 0.9998 to 0.9999. Detection limits (S/N = 3) were 5-15 ng mL(-1) using a photodiode array UV detection at a wavelength of 240 nm. The relative standard deviations were between 2.8% and 3.5% (n = 5, progesterone as the internal standard). The diode array UV spectrum used can distinguish the analytes from the interference in the complex sample matrix, which is useful in biological and clinical sample analysis. (C) 2011 Elsevier B.V. All rights reserved.
英文摘要A novel method that combines two concentration techniques, off-line centrifuge microextraction (CME) and on-line sweeping, is used to determine trace steroids in urine by micellar electrokinetic chromatography (MEKC). The CME-sweeping-MEKC is a promising technique, which has a variety of merits such as high sensitivity, rapid operation, minimal cost, and high sample throughput capability. Using CME-sweeping, over a 500-fold increase in sensitivity could be obtained as compared with the normal hydrodynamic injection without sample stacking. The linear range was 0.05-1 mu g mL(-1) with the square of the correlation coefficients ranging from 0.9998 to 0.9999. Detection limits (S/N = 3) were 5-15 ng mL(-1) using a photodiode array UV detection at a wavelength of 240 nm. The relative standard deviations were between 2.8% and 3.5% (n = 5, progesterone as the internal standard). The diode array UV spectrum used can distinguish the analytes from the interference in the complex sample matrix, which is useful in biological and clinical sample analysis. (C) 2011 Elsevier B.V. All rights reserved.
WOS标题词Science & Technology ; Physical Sciences
学科主题Chemistry
类目[WOS]Chemistry, Analytical
研究领域[WOS]Chemistry
关键词[WOS]MICELLAR ELECTROKINETIC CHROMATOGRAPHY ; DENSITY-GRADIENT ULTRACENTRIFUGATION ; PERFORMANCE LIQUID-CHROMATOGRAPHY ; REVERSE MIGRATING MICELLES ; IONIZATION MASS-SPECTROMETRY ; WALLED CARBON NANOTUBES ; METAL-ION COMPLEXES ; CAPILLARY-ELECTROPHORESIS ; ONLINE CONCENTRATION ; NEUTRAL ANALYTES
收录类别SCI
资助信息National Natural Science Foundation of China[20375028]; National Basic Research Program, China[2003CB415005]; Chinese Academy of Sciences[KSCX2-SW-128]
语种英语
WOS记录号WOS:000295393000066
公开日期2011-12-22
源URL[http://ir.ihb.ac.cn/handle/342005/16457]  
专题水生生物研究所_水环境工程研究中心_期刊论文
作者单位1.Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
2.Chinese Acad Sci, State Key Lab Freshwater Ecol & Biotechnol, Inst Hydrobiol, Wuhan 430072, Peoples R China
推荐引用方式
GB/T 7714
Fang, Huaifang,Yang, Fangxing,Sun, Junling,et al. Centrifuge microextraction coupled with sweeping-MEKC to analyze trace steroid hormones in urine samples[J]. TALANTA,2011,85(4):2148-2153.
APA Fang, Huaifang,Yang, Fangxing,Sun, Junling,Tian, Yun,Zeng, Zhaorui,&Xu, Ying.(2011).Centrifuge microextraction coupled with sweeping-MEKC to analyze trace steroid hormones in urine samples.TALANTA,85(4),2148-2153.
MLA Fang, Huaifang,et al."Centrifuge microextraction coupled with sweeping-MEKC to analyze trace steroid hormones in urine samples".TALANTA 85.4(2011):2148-2153.

入库方式: OAI收割

来源:水生生物研究所

浏览0
下载0
收藏0
其他版本