中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Serum tumor marker detection on PEGylated lipid membrane using biosensor based on total internal reflection imaging ellipsometry

文献类型:期刊论文

作者Zhang YB; Chen YY(陈艳艳); Jin G(靳刚)
刊名Sensors and Actuators B-Chemical
出版日期2011
卷号159期号:1页码:121-125
通讯作者邮箱yychen2006@sinano.ac.cn; gajin@imech.ac.cn
关键词Pegylated Phospholipid Membrane Total Internal Reflection Imaging Ellipsometry Ca19-9 Resectable Pancreatic Adenocarcinoma Perioperative Ca19-9 Levels (18)Fdg-Pet Examination Predict Stage Protein Adsorption Immobilization Surfaces Antigen Cancer
ISSN号0925-4005
产权排序[Zhang, Yibang; Chen, Yanyan; Jin, Gang] Chinese Acad Sci, Suzhou Inst Nanotech & Nanobion, Suzhou 215125, Jiangsu, Peoples R China; [Zhang, Yibang; Jin, Gang] Chinese Acad Sci, Inst Biophys, Beijing 100101, Peoples R China; [Zhang, Yibang] Chinese Acad Sci, Grad Univ, Suzhou 100049, Peoples R China; [Jin, Gang] Chinese Acad Sci, Inst Mech, Beijing 100190, Peoples R China
通讯作者Chen, YY (reprint author), Chinese Acad Sci, Suzhou Inst Nanotech & Nanobion, Suzhou 215125, Jiangsu, Peoples R China
合作状况国内
中文摘要We describe highly sensitive, label-free, real time detection of the biomarker CA19-9 using microarray biosensors based on total internal reflection imaging ellipsometry (TIRIE), in which anti-CA19-9 is immobilized onto the PEGylated phospholipid membrane. Strong resistance against non-specific adsorption of PEGylated lipid membrane allows direct serum assay without the blocking agent. We find that PEG density has an influence on antibody assembly and only a proper amount of PEG is appropriate for antigen binding. Two different methods for antibody assembly are compared and finally protein A is preferred due to its higher protein binding efficiency. The estimated detection limit of CA19-9 is 18.2 U/ml, which is lower than the cut-off value for normal level (37 U/ml). Regression analysis between the results of microarray biosensor and electrochemiluminescence immunoassay (ECLIA) suggests a high correlation (R = 0.989). The capability for real-time monitoring of tumor marker with high sensitivity and selectivity in clinically relevant samples opens up substantial possibilities for early cancer diagnosis and treatment. (C) 2011 Elsevier B.V. All rights reserved.
学科主题Chemistry; Electrochemistry; Instruments & Instrumentation
分类号二类/Q1
类目[WOS]Chemistry, Analytical ; Electrochemistry ; Instruments & Instrumentation
研究领域[WOS]Chemistry ; Electrochemistry ; Instruments & Instrumentation
关键词[WOS]RESECTABLE PANCREATIC ADENOCARCINOMA ; PERIOPERATIVE CA19-9 LEVELS ; (18)FDG-PET EXAMINATION ; PREDICT STAGE ; PROTEIN ; ADSORPTION ; IMMOBILIZATION ; SURFACES ; ANTIGEN ; CANCER
收录类别SCI ; EI
资助信息The authors would like to gratefully acknowledge financial supports from Ministry of Science and Technology of China (2008AA02Z419, 2009CB320302), Natural Science Foundation (10804083, 20845003) of China, Chinese Academy of Sciences (KJCX2-YW-M04, KJCX2-YW-M03) and Key Laboratory of Microgravity, Institute of Mechanics, CAS.
原文出处http://dx.doi.org/10.1016/j.snb.2011.06.059
语种英语
WOS记录号WOS:000295745900017
公开日期2012-04-01
源URL[http://dspace.imech.ac.cn/handle/311007/45066]  
专题力学研究所_国家微重力实验室
推荐引用方式
GB/T 7714
Zhang YB,Chen YY,Jin G. Serum tumor marker detection on PEGylated lipid membrane using biosensor based on total internal reflection imaging ellipsometry[J]. Sensors and Actuators B-Chemical,2011,159(1):121-125.
APA Zhang YB,陈艳艳,&靳刚.(2011).Serum tumor marker detection on PEGylated lipid membrane using biosensor based on total internal reflection imaging ellipsometry.Sensors and Actuators B-Chemical,159(1),121-125.
MLA Zhang YB,et al."Serum tumor marker detection on PEGylated lipid membrane using biosensor based on total internal reflection imaging ellipsometry".Sensors and Actuators B-Chemical 159.1(2011):121-125.

入库方式: OAI收割

来源:力学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。