Improvement for sensitivity of biosensor with total internal reflection imaging ellipsometry (TIRIE)
文献类型:期刊论文
作者 | Liu L(刘丽)![]() ![]() ![]() ![]() ![]() |
刊名 | Thin Solid Films
![]() |
出版日期 | 2011 |
卷号 | 519期号:9页码:2758-2762 |
通讯作者邮箱 | gajin@imech.ac.cn |
关键词 | Sensitivity Improvement Imaging Ellipsometry Total Internal Reflection Biosensor Hbsag Detection Plasmon Enhanced Ellipsometry Surface Resonance Sensors |
ISSN号 | 0040-6090 |
产权排序 | [Liu, Li; Meng, Yong-hong; Chen, She; Jin, Gang] Chinese Acad Sci, Natl Micrograv Lab, Inst Mech, Beijing 100190, Peoples R China; [Liu, Li] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China; [Chen, Yan-yan] Chinese Acad Sci, Inst Nanotech & Nanobion, Suzhou 215125, Peoples R China |
通讯作者 | Jin, G (reprint author), Chinese Acad Sci, Natl Micrograv Lab, Inst Mech, 15 Bei Si Huan W Rd, Beijing 100190, Peoples R China |
合作状况 | 国内 |
中文摘要 | The biosensor based on the total internal reflection imaging ellipsometry (TIRIE) is realized as an automatic analysis method for protein interaction processes in real-time, with high throughput and label-free. An evanescent wave is used as the optical probe to monitor bio-molecular interactions on a chip surface with a high sensitivity due to its phase sensitive property. In this paper, the technique is optimized with a polarization setting, a spectroscopic light source and a low noise CCD detector to improve the performance of the biosensor in sensitivity and detection limit, as evidenced by a quantitative detection of Hepatitis B virus surface antigen (HbsAg) with concentrations of 8, 16, 32, 64, 125 and 250 ng/ml. The sensitivity is increased by one order of magnitude and the detection limit has been extended more than 50 times for HbsAg detection. (C) 2011 Elsevier B.V. All rights reserved. |
学科主题 | Materials Science; Physics |
分类号 | 二类/Q2 |
类目[WOS] | Materials Science, Multidisciplinary ; Materials Science, Coatings & Films ; Physics, Applied ; Physics, Condensed Matter |
研究领域[WOS] | Materials Science ; Physics |
关键词[WOS] | PLASMON ENHANCED ELLIPSOMETRY ; SURFACE ; RESONANCE ; SENSORS |
收录类别 | SCI ; EI |
原文出处 | http://dx.doi.org/10.1016/j.tsf.2010.12.130 |
语种 | 英语 |
WOS记录号 | WOS:000289174200041 |
公开日期 | 2012-04-01 |
源URL | [http://dspace.imech.ac.cn/handle/311007/45100] ![]() |
专题 | 力学研究所_国家微重力实验室 |
推荐引用方式 GB/T 7714 | Liu L,Chen YY,Meng YH,et al. Improvement for sensitivity of biosensor with total internal reflection imaging ellipsometry (TIRIE)[J]. Thin Solid Films,2011,519(9):2758-2762. |