Improvement for sensitivity of biosensor with total internal reflection imaging ellipsometry (TIRIE)

文献类型:会议论文

作者Liu L(刘丽); Chen YY(陈艳艳); Meng YH(孟永宏); Chen S(陈涉); Jin G(靳刚)
出版日期2011
会议名称5th International Conference on Spectroscopic Ellipsometry
会议日期MAY 23-29, 2010
会议地点Albany, NY
通讯作者邮箱gajin@imech.ac.cn
关键词Sensitivity improvement Imaging ellipsometry Total internal reflection Biosensor HbsAg detection
卷号519
期号9
页码2758-2762
通讯作者Jin, G (reprint author), Chinese Acad Sci, Natl Micrograv Lab, Inst Mech, 15 Bei Si Huan W Rd, Beijing 100190, Peoples R China
中文摘要The biosensor based on the total internal reflection imaging ellipsometry (TIRIE) is realized as an automatic analysis method for protein interaction processes in real-time, with high throughput and label-free. An evanescent wave is used as the optical probe to monitor bio-molecular interactions on a chip surface with a high sensitivity due to its phase sensitive property. In this paper, the technique is optimized with a polarization setting, a spectroscopic light source and a low noise CCD detector to improve the performance of the biosensor in sensitivity and detection limit, as evidenced by a quantitative detection of Hepatitis B virus surface antigen (HbsAg) with concentrations of 8, 16, 32, 64, 125 and 250 ng/ml. The sensitivity is increased by one order of magnitude and the detection limit has been extended more than 50 times for HbsAg detection. (C) 2011 Elsevier B.V. All rights reserved.
收录类别CPCI
合作状况国内
产权排序Chinese Acad Sci, Natl Micrograv Lab, Inst Mech, Beijing 100190, Peoples R China; Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China; Chinese Acad Sci, Inst Nanotech & Nanobion, Suzhou 215125, Peoples R China
会议主办者Univ Albany, Coll Nanoscale & Engn
会议网址http://dx.doi.org/10.1016/j.tsf.2010.12.130
会议录THIN SOLID FILMS
会议录出版者ELSEVIER SCIENCE SA
学科主题Materials Science, Multidisciplinary; Materials Science, Coatings & Films; Physics, Applied; Physics, Condensed Matter
会议录出版地PO BOX 564, 1001 LAUSANNE, SWITZERLAND
语种英语
ISSN号0040-6090
源URL[http://dspace.imech.ac.cn/handle/311007/45319]  
专题力学研究所_国家微重力实验室
推荐引用方式
GB/T 7714
Liu L,Chen YY,Meng YH,et al. Improvement for sensitivity of biosensor with total internal reflection imaging ellipsometry (TIRIE)[C]. 见:5th International Conference on Spectroscopic Ellipsometry. Albany, NY. MAY 23-29, 2010.http://dx.doi.org/10.1016/j.tsf.2010.12.130.