中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Bunch length measurement using a traveling wave RF deflector

文献类型:期刊论文

作者Zhang, JR(张敬如) ; Dai, JP戴建枰) ; Gu, Q(顾强) ; Pei, GX ; Zhao, MH(赵明华) ; Zhong, SP(钟少鹏) ; Wang, XT ; Chen, YZ(陈永忠) ; Hou, M
刊名CHINESE PHYSICS C
出版日期2010
卷号34期号:1页码:5
关键词RF deflector bunch length RF gun HEM(11) mode
ISSN号1674-1137
通讯作者Zhang, JR (reprint author), CAS, Inst High Energy Phys, Beijing 100049, Peoples R China
英文摘要RF deflectors can be used for bunch length measurement with high resolution. This paper describes a completed S-band traveling wave RF deflector and the bunch length measurement of the electron beam produced by the photocathode RF gun of the Shanghai DUV-FEL facility. This is the first time that such a transverse RF deflector has been developed and used to measure the bunch length of picosecond order in China. The deflector's VSWR, is 1.06, the whole attenuation 0.5 dB, and the bandwidth 4.77 MHz for VSWR less than I. I. With a laser pulse width of 8.5 ps, beam energy of 4.2 MeV, and bunch charge of 0.64 nC, the bunch lengths for different RF input power into the deflector were measured, and an averaged rms bunch length of 5.25 ps was obtained. A YAG crystal is used as a screen downstream of the deflector, with the calibrated value of 1 pix = 136 mu m.
学科主题Physics
收录类别SCI
语种英语
WOS记录号WOS:000274095100026
公开日期2012-04-11
源URL[http://ir.sinap.ac.cn/handle/331007/6857]  
专题上海应用物理研究所_中科院上海应用物理研究所2004-2010年
推荐引用方式
GB/T 7714
Zhang, JR,Dai, JP戴建枰),Gu, Q,et al. Bunch length measurement using a traveling wave RF deflector[J]. CHINESE PHYSICS C,2010,34(1):5.
APA Zhang, JR.,Dai, JP戴建枰).,Gu, Q.,Pei, GX.,Zhao, MH.,...&Hou, M.(2010).Bunch length measurement using a traveling wave RF deflector.CHINESE PHYSICS C,34(1),5.
MLA Zhang, JR,et al."Bunch length measurement using a traveling wave RF deflector".CHINESE PHYSICS C 34.1(2010):5.

入库方式: OAI收割

来源:上海应用物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。