Effect of solenoidal magnetic field on the multipacting effect in sub-harmonic buncher of Shanghai synchrotron radiation facility (SSRF) linac

文献类型:期刊论文

作者Zhang, M(张猛) ; Zhao, MH(赵明华) ; Wang, BL(汪宝亮)
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
出版日期2009
卷号599期号:40577页码:5
关键词Sub-harmonic buncher Multipacting effect Solenoidal magnetic field Bucking coil compensation
ISSN号0168-9002
通讯作者Zhang, M (reprint author), Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
英文摘要During the commissioning of the sub-harmonic buncher of the Shanghai synchrotron radiation facility (SSRF) linac, unexpected multipacting effect is observed, which limits the increase of the input power when the focusing coils are added. A novel method of adding bucking coils is very effective to suppress this effect after investigating different magnetic field configurations. The experimental observations and simulation results of multipacting effect are presented. In addition, details of the multipacting process are analyzed. (c) 2008 Elsevier B.V. All rights reserved.
学科主题Instruments & Instrumentation; Nuclear Science & Technology; Physics; Spectroscopy
收录类别SCI
语种英语
WOS记录号WOS:000263706500001
公开日期2012-04-11
源URL[http://ir.sinap.ac.cn/handle/331007/6899]  
专题上海应用物理研究所_中科院上海应用物理研究所2004-2010年
推荐引用方式
GB/T 7714
Zhang, M,Zhao, MH,Wang, BL. Effect of solenoidal magnetic field on the multipacting effect in sub-harmonic buncher of Shanghai synchrotron radiation facility (SSRF) linac[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2009,599(40577):5.
APA Zhang, M,Zhao, MH,&Wang, BL.(2009).Effect of solenoidal magnetic field on the multipacting effect in sub-harmonic buncher of Shanghai synchrotron radiation facility (SSRF) linac.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,599(40577),5.
MLA Zhang, M,et al."Effect of solenoidal magnetic field on the multipacting effect in sub-harmonic buncher of Shanghai synchrotron radiation facility (SSRF) linac".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 599.40577(2009):5.

入库方式: OAI收割

来源:上海应用物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。