Sequence-specific DNA detection by using biocatalyzed electrochemiluminescence and non-fouling surfaces
文献类型:期刊论文
作者 | Zhang, LY(张兰勇) ; Li, D(李迪) ; Meng, WL ; Huang, Q ; Su, Y ; Wang, LH(王丽华) ; Song, SP(宋世平) ; Fan, CH(樊春海) |
刊名 | BIOSENSORS & BIOELECTRONICS
![]() |
出版日期 | 2009 |
卷号 | 25期号:2页码:5 |
关键词 | DNA sensor Enzyme Electrochemiluminescence Non-fouling |
ISSN号 | 0956-5663 |
通讯作者 | Li, D (reprint author), Chinese Acad Sci, Phys Biol Lab, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China |
英文摘要 | We herein report a DNA sensor for the sequence-specific DNA detection by using glucose oxidase-based biocatalyzed electrochemiluminescence and non-fouling surfaces. In this design, a glucose oxidase-labeled sandwich-type DNA sensor was built on a non-fouling surfaces made of a mixed self-assembled monolayers (SAMs) incorporating thiolated oligonucleotides and oligo(ethylene glycol) (OEG) thiols (SH-DNA/OEG). The sequence-specific DNA sensing was accomplished by the electrochemiluminesce (ECL) signal of luminol with the in-situ generated H(2)O(2). The protein-resistant non-fouling surfaces significantly suppressed the non-specific adsorption of enzyme label on electrode and reduced the background noise of this sensor. This sensor was able to detect as little as 1 pM of target DNA in pure buffer matrix. In complicated biological fluids such as human serum, this non-fouling platform-based sensor also revealed superior performance over conventional sandwich-type DNA sensors with mercaptohexanol (MCH)-coated surfaces. This strategy combines the high sensitivity of enzymatic amplified ECL and protein-resistant non-fouling platform, which is expected to be extended to a range of biological detection. (C) 2009 Elsevier B.V. All rights reserved. |
学科主题 | Biophysics; Biotechnology & Applied Microbiology; Chemistry; Electrochemistry; Science & Technology - Other Topics |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000270764300017 |
公开日期 | 2012-04-11 |
源URL | [http://ir.sinap.ac.cn/handle/331007/7043] ![]() |
专题 | 上海应用物理研究所_中科院上海应用物理研究所2004-2010年 |
推荐引用方式 GB/T 7714 | Zhang, LY,Li, D,Meng, WL,et al. Sequence-specific DNA detection by using biocatalyzed electrochemiluminescence and non-fouling surfaces[J]. BIOSENSORS & BIOELECTRONICS,2009,25(2):5. |
APA | Zhang, LY.,Li, D.,Meng, WL.,Huang, Q.,Su, Y.,...&Fan, CH.(2009).Sequence-specific DNA detection by using biocatalyzed electrochemiluminescence and non-fouling surfaces.BIOSENSORS & BIOELECTRONICS,25(2),5. |
MLA | Zhang, LY,et al."Sequence-specific DNA detection by using biocatalyzed electrochemiluminescence and non-fouling surfaces".BIOSENSORS & BIOELECTRONICS 25.2(2009):5. |
入库方式: OAI收割
来源:上海应用物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。