Dispersive liquid-liquid microextraction combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples
文献类型:期刊论文
作者 | Jia XY ; Han Y ; Liu XL ; Duan TC ; Chen HT |
刊名 | microchimica acta |
出版日期 | 2010 |
卷号 | 171期号:1-2页码:49-56 |
ISSN号 | 0026-3672 |
关键词 | ATOMIC-ABSORPTION-SPECTROMETRY CLOUD-POINT EXTRACTION SOLID-PHASE EXTRACTION VAPORIZATION ICP-MS ENVIRONMENTAL-SAMPLES ARRAY DETECTION TRACE AMOUNTS PRECONCENTRATION PB CD |
通讯作者 | duan tc |
中文摘要 | dispersive liquid-liquid microextraction (dllme) was combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples. the metal elements were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using dllme. under the optimized conditions, the enrichment factors for cd, pb and bi are 460, 900 and 645 in 5 ml of a spiked water sample, respectively. the calibration graphs for the three metals are linear in the range of concentrations from < 10 ng l-1 to 1,000 ng l-1. the detection limits are 0.5 ng l-1, 1.6 ng l-1 and 4.7 ng l-1, respectively. the relative standard deviations for ten replicate measurements of 50 ng l-1 cadmium, lead and bismuth are 2.6%, 6.7%, and 4.9%, respectively, and the relative recoveries in various water samples at a spiking level of 50 ng l-1 range from 83.6% to 107.0%. |
收录类别 | SCI收录期刊论文 |
语种 | 英语 |
WOS记录号 | WOS:000281669900007 |
公开日期 | 2012-04-26 |
源URL | [http://ir.ciac.jl.cn/handle/322003/43476] |
专题 | 长春应用化学研究所_长春应用化学研究所知识产出_期刊论文 |
推荐引用方式 GB/T 7714 | Jia XY,Han Y,Liu XL,et al. Dispersive liquid-liquid microextraction combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples[J]. microchimica acta,2010,171(1-2):49-56. |
APA | Jia XY,Han Y,Liu XL,Duan TC,&Chen HT.(2010).Dispersive liquid-liquid microextraction combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples.microchimica acta,171(1-2),49-56. |
MLA | Jia XY,et al."Dispersive liquid-liquid microextraction combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples".microchimica acta 171.1-2(2010):49-56. |
入库方式: OAI收割
来源:长春应用化学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。