中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Dispersive liquid-liquid microextraction combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples

文献类型:期刊论文

作者Jia XY ; Han Y ; Liu XL ; Duan TC ; Chen HT
刊名microchimica acta
出版日期2010
卷号171期号:1-2页码:49-56
ISSN号0026-3672
关键词ATOMIC-ABSORPTION-SPECTROMETRY CLOUD-POINT EXTRACTION SOLID-PHASE EXTRACTION VAPORIZATION ICP-MS ENVIRONMENTAL-SAMPLES ARRAY DETECTION TRACE AMOUNTS PRECONCENTRATION PB CD
通讯作者duan tc
中文摘要dispersive liquid-liquid microextraction (dllme) was combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples. the metal elements were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using dllme. under the optimized conditions, the enrichment factors for cd, pb and bi are 460, 900 and 645 in 5 ml of a spiked water sample, respectively. the calibration graphs for the three metals are linear in the range of concentrations from < 10 ng l-1 to 1,000 ng l-1. the detection limits are 0.5 ng l-1, 1.6 ng l-1 and 4.7 ng l-1, respectively. the relative standard deviations for ten replicate measurements of 50 ng l-1 cadmium, lead and bismuth are 2.6%, 6.7%, and 4.9%, respectively, and the relative recoveries in various water samples at a spiking level of 50 ng l-1 range from 83.6% to 107.0%.
收录类别SCI收录期刊论文
语种英语
WOS记录号WOS:000281669900007
公开日期2012-04-26
源URL[http://ir.ciac.jl.cn/handle/322003/43476]  
专题长春应用化学研究所_长春应用化学研究所知识产出_期刊论文
推荐引用方式
GB/T 7714
Jia XY,Han Y,Liu XL,et al. Dispersive liquid-liquid microextraction combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples[J]. microchimica acta,2010,171(1-2):49-56.
APA Jia XY,Han Y,Liu XL,Duan TC,&Chen HT.(2010).Dispersive liquid-liquid microextraction combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples.microchimica acta,171(1-2),49-56.
MLA Jia XY,et al."Dispersive liquid-liquid microextraction combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples".microchimica acta 171.1-2(2010):49-56.

入库方式: OAI收割

来源:长春应用化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。