Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting

文献类型:期刊论文

作者L. E. Murr ; K. N. Amato ; S. J. Li ; Y. X. Tian ; X. Y. Cheng ; S. M. Gaytan ; E. Martinez ; P. W. Shindo ; F. Medina ; R. B. Wicker
刊名Journal of the Mechanical Behavior of Biomedical Materials
出版日期2011
卷号4期号:7页码:1396-1411
关键词biomedical applications titanium-alloys scaffolds foams design
ISSN号1751-6161
中文摘要Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily alpha-phase acicular platelets while the mesh and foam structures were characterized by alpha'-martensite with some residual alpha. The Co-29Cr-6Mo containing 0.22% C formed columnar (directional) Cr(23)C(6) carbides spaced similar to 2 mu m in the build direction, while HIP-annealed Co-Cr alloy exhibited an intrinsic stacking fault microstructure. A log-log plot of relative stiffness versus relative density for Ti-6Al-4V and Co-29Cr-6Mo open-cellular mesh and foams resulted in a fitted line with a nearly ideal slope, n = 2.1. A stress shielding design graph constructed from these data permitted mesh and foam implant prototypes to be fabricated for compatible bone stiffness. (C) 2011 Elsevier Ltd. All rights reserved.
原文出处://WOS:000294187500050
公开日期2012-04-13
源URL[http://210.72.142.130/handle/321006/30597]  
专题金属研究所_中国科学院金属研究所
推荐引用方式
GB/T 7714
L. E. Murr,K. N. Amato,S. J. Li,et al. Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting[J]. Journal of the Mechanical Behavior of Biomedical Materials,2011,4(7):1396-1411.
APA L. E. Murr.,K. N. Amato.,S. J. Li.,Y. X. Tian.,X. Y. Cheng.,...&R. B. Wicker.(2011).Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting.Journal of the Mechanical Behavior of Biomedical Materials,4(7),1396-1411.
MLA L. E. Murr,et al."Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting".Journal of the Mechanical Behavior of Biomedical Materials 4.7(2011):1396-1411.

入库方式: OAI收割

来源:金属研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。