EIS monitoring study of atmospheric corrosion under variable relative humidity
文献类型:期刊论文
作者 | C. L. Li ; Y. T. Ma ; Y. Li ; F. H. Wang |
刊名 | Corrosion Science
![]() |
出版日期 | 2010 |
卷号 | 52期号:11页码:3677-3686 |
关键词 | EIS Weight loss Atmospheric corrosion electrochemical impedance spectroscopy galvanized steel electrolyte layer environment aluminum chloride sensors zinc iron |
ISSN号 | 0010-938X |
中文摘要 | Electrochemical impedance spectroscopy (EIS) technique was used to investigate atmospheric corrosion in laboratory simulated environments with variable relative humidity (RH) and fixed Cl(-) content. The results show the suitability of EIS for analyzing electrochemical corrosion behaviour at 5-100% RH. At 5-30% RH, EIS spectra reflected the character of the electrode, whereas at 40-100% RH, the model of EIS spectra was established with the help of surface analysis. From 70% RH, the film resistance (R(r)) reflects the degree of corrosion and the charge transfer resistance (R(t)) provides quantitative representation of the corrosion rate, which were verified by weight loss tests. (C) 2010 Elsevier Ltd. All rights reserved. |
原文出处 | |
公开日期 | 2012-04-13 |
源URL | [http://210.72.142.130/handle/321006/31202] ![]() |
专题 | 金属研究所_中国科学院金属研究所 |
推荐引用方式 GB/T 7714 | C. L. Li,Y. T. Ma,Y. Li,et al. EIS monitoring study of atmospheric corrosion under variable relative humidity[J]. Corrosion Science,2010,52(11):3677-3686. |
APA | C. L. Li,Y. T. Ma,Y. Li,&F. H. Wang.(2010).EIS monitoring study of atmospheric corrosion under variable relative humidity.Corrosion Science,52(11),3677-3686. |
MLA | C. L. Li,et al."EIS monitoring study of atmospheric corrosion under variable relative humidity".Corrosion Science 52.11(2010):3677-3686. |