中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
EIS monitoring study of atmospheric corrosion under variable relative humidity

文献类型:期刊论文

作者C. L. Li ; Y. T. Ma ; Y. Li ; F. H. Wang
刊名Corrosion Science
出版日期2010
卷号52期号:11页码:3677-3686
关键词EIS Weight loss Atmospheric corrosion electrochemical impedance spectroscopy galvanized steel electrolyte layer environment aluminum chloride sensors zinc iron
ISSN号0010-938X
中文摘要Electrochemical impedance spectroscopy (EIS) technique was used to investigate atmospheric corrosion in laboratory simulated environments with variable relative humidity (RH) and fixed Cl(-) content. The results show the suitability of EIS for analyzing electrochemical corrosion behaviour at 5-100% RH. At 5-30% RH, EIS spectra reflected the character of the electrode, whereas at 40-100% RH, the model of EIS spectra was established with the help of surface analysis. From 70% RH, the film resistance (R(r)) reflects the degree of corrosion and the charge transfer resistance (R(t)) provides quantitative representation of the corrosion rate, which were verified by weight loss tests. (C) 2010 Elsevier Ltd. All rights reserved.
原文出处://WOS:000282561300012
公开日期2012-04-13
源URL[http://210.72.142.130/handle/321006/31202]  
专题金属研究所_中国科学院金属研究所
推荐引用方式
GB/T 7714
C. L. Li,Y. T. Ma,Y. Li,et al. EIS monitoring study of atmospheric corrosion under variable relative humidity[J]. Corrosion Science,2010,52(11):3677-3686.
APA C. L. Li,Y. T. Ma,Y. Li,&F. H. Wang.(2010).EIS monitoring study of atmospheric corrosion under variable relative humidity.Corrosion Science,52(11),3677-3686.