中文摘要 | Electrochemical impedance spectra of 316 stainless steel in NaCl solutions with different concentration, which were measured by using reference electrode systems with different internal resistance, were presented. The results showed that the large internal resistance of reference electrode system induced capacitive high frequency phase shifting impedance measurement. It was also found that high frequency phases shifts were reduced with the decrease of solution resistance and the internal resistance of reference electrode system. |
原文出处 | |
公开日期 | 2012-04-14 |
源URL | [http://ir.imr.ac.cn/handle/321006/36698] ![]() |
专题 | 金属研究所_中国科学院金属研究所 |
推荐引用方式 GB/T 7714 | M. C. Li,C. L. Zeng,H. C. Lin,et al. Effect of internal resistance of reference electrode system on electrochemical impedance spectroscopy[J]. Bulletin of Electrochemistry,2001,17(7):299-302. |
APA | M. C. Li,C. L. Zeng,H. C. Lin,&C. N. Cao.(2001).Effect of internal resistance of reference electrode system on electrochemical impedance spectroscopy.Bulletin of Electrochemistry,17(7),299-302. |
MLA | M. C. Li,et al."Effect of internal resistance of reference electrode system on electrochemical impedance spectroscopy".Bulletin of Electrochemistry 17.7(2001):299-302. |