中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Comparison of flux measurement by open-path and close-path eddy covariance systems

文献类型:SCI/SSCI论文

作者Song X. ; Yu G. R. ; Liu Y. F. ; Sun X. M. ; Ren C. Y. ; Wen X. F.
发表日期2005
关键词eddy covariance technique open-path eddy covariance close-path eddy covariance delay time spectrum analyze flux co2 analyzers water-vapor carbon-dioxide forest exchange field fluctuations surface sensor
英文摘要For flux measurement, the eddy covariance technique supplies a possibility to directly measure the exchange between vegetation and atmosphere; and there are two kinds of eddy covariance systems, open-path and close-path systems. For the system error, it may result in difference of flux measurements by two systems. Therefore, it is necessary to compare the measured results from them. ChinaFLUX covers of eight sites applied the micrometeorological method, in which Changbai Mountains (CBS) and Qianyanzhou (QYZ) carried out open-path eddy covariance (OPEC) and close-path eddy covariance (CPEC) measurements synchronously. In this paper the data sets of CBS and QYZ were employed. The delay time of close-path analyzer to the open-path analyzer was calculated; the spectra and cospectra of time-series data of OPEC and CPEC were analyzed; the open-path flux measurement was used as a standard comparison, the close-path flux measurement results were evaluated. The results show that, at two sites the delay time Of CO2 density for close-path analyzer was about 7.0-8.0 s, H2O density about 8.0-9.0 s; the spectrum from the open-path, close-path and 3D sonic anemometer was consistent with the expected -2/3 slope (log-log plot), and the cospectra showed the expected slope of -4/3 in the internal subrange; the CO2 flux measured by the close-path sensor was about 84% of that of open-path measurement at QYZ, about 80% at CBS, and the latent heat flux was balanced for two systems at QYZ, 86% at CBS. From the flux difference between open-path and close-path analyzers, it could be inferred that the attenuation of turbulent fluctuations in flow through tube of CPEC affected H2O flux more significantly than CO2 flux. The gap between two systems was bigger at CBS than at QYZ; the diurnal variation in CO2 flux Of two measurement systems was very consistent.
出处Science in China Series D-Earth Sciences
48
74-84
收录类别SCI
语种英语
ISSN号1006-9313
源URL[http://ir.igsnrr.ac.cn/handle/311030/23059]  
专题地理科学与资源研究所_历年回溯文献
推荐引用方式
GB/T 7714
Song X.,Yu G. R.,Liu Y. F.,et al. Comparison of flux measurement by open-path and close-path eddy covariance systems. 2005.

入库方式: OAI收割

来源:地理科学与资源研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。