中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Slurry Nebulization-Inductively Coupled Plasma Mass Spectrometry with Solution Calibration for Determination of Ultra-Trace Boron in High Pure Nuclear Graphite Powder

文献类型:期刊论文

作者Xin-Li L ; Tai-Cheng D ; Yi H ; Xiao-Yu J ; Wei-Na Z ; Hang-Ting C
刊名chinese journal of analytical chemistry
出版日期2010
卷号38期号:5页码:693-696
关键词HIGH-PURITY GRAPHITE ATOMIC EMISSION-SPECTROMETRY LASER-ABLATION ABSORPTION-SPECTROMETRY ICP-MS ELEMENTS INJECTION CADMIUM CARBIDE LEAD
ISSN号0253-3820
通讯作者hang-ting c
中文摘要the method of slurry nebulization-inductively coupled plasma mass spectrometry ( sn-icp-ms) was developed for the direct determination of trace boron in high purity graphite powders. the particle size was controlled <5 mu m after the graphite powders was ground and sifted. polyvinylpyrrolidone (pvp) was used as the dispersant in slurry preparation. the optimal mass ratio of pvp to the graphite was found to be 0.5. well proportioned and stable slurry solution was obtained by magnetic stirrer. about 0.1 mol/l nh4oh as the aqueous medium could provide the optimal ph of 10 for the stable slurry and eliminate the memory effect of b. icp-ms was operated in a higher resolution mode (0.6 amu) to eliminate the interference with the matrix c-12 by peak tailing. oxygen was added into the plasma at a flow rate of 60 ml/min, to resolve carbon deposition on the sampler and skimmer cones and accelerate particle dissociation in the plasma. external calibration with aqueous solution standards was established for quantification. beryllium was chosen as the internal standard to evaluate the efficiency of matrix effect correction. a correlation coefficient of 0.9995 for boron concentrations from 2 to 200 mu g/l was obtained with a detection limit (3s) of 0.095 mu g/g. as a practical application, with the advantage of simple, quick and low losing, the proposed method was applied to determine the trace boron in four nuclear graphite samples ( claimed 99.999% purity), with the satisfactory recoveries for the spike tests in the range of 97.2% - 103.1%.
收录类别SCI收录期刊论文
语种中文
WOS记录号WOS:000278208600017
公开日期2012-06-06
源URL[http://ir.ciac.jl.cn/handle/322003/43691]  
专题长春应用化学研究所_长春应用化学研究所知识产出_期刊论文
推荐引用方式
GB/T 7714
Xin-Li L,Tai-Cheng D,Yi H,et al. Slurry Nebulization-Inductively Coupled Plasma Mass Spectrometry with Solution Calibration for Determination of Ultra-Trace Boron in High Pure Nuclear Graphite Powder[J]. chinese journal of analytical chemistry,2010,38(5):693-696.
APA Xin-Li L,Tai-Cheng D,Yi H,Xiao-Yu J,Wei-Na Z,&Hang-Ting C.(2010).Slurry Nebulization-Inductively Coupled Plasma Mass Spectrometry with Solution Calibration for Determination of Ultra-Trace Boron in High Pure Nuclear Graphite Powder.chinese journal of analytical chemistry,38(5),693-696.
MLA Xin-Li L,et al."Slurry Nebulization-Inductively Coupled Plasma Mass Spectrometry with Solution Calibration for Determination of Ultra-Trace Boron in High Pure Nuclear Graphite Powder".chinese journal of analytical chemistry 38.5(2010):693-696.

入库方式: OAI收割

来源:长春应用化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。