Microwave plasma torch-atomic emission spectrometry for the on-line determination of rare earth elements based on flow injection preconcentration by TiO(2)-graphene composite
文献类型:期刊论文
作者 | Zhang JL ; Cheng RM ; Tong SS ; Gu XW ; Quan XJ ; Liu YL ; Jia Q ; Jia JB |
刊名 | talanta
![]() |
出版日期 | 2011 |
卷号 | 86页码:114-120 |
关键词 | SOLID-PHASE EXTRACTION ICP-OES DETERMINATION COLUMN PRECONCENTRATION PHOTOCATALYTIC ACTIVITY MASS SPECTROMETRY MESOPOROUS TIO2 HYDROGEN EVOLUTION TITANIUM-DIOXIDE WATER SAMPLES CARBON |
ISSN号 | 0039-9140 |
通讯作者 | jia q |
中文摘要 | in this work, we synthesized tio(2)-graphene composite as a novel preconcentration material. it was enclosed in a microcolumn in the on-line flow injection system to adsorb trace light (la), medium (tb), and heavy (ho) rare earth elements (rees) prior to their determinations by microwave plasma torch-atomic emission spectrometry (mpt-aes). various experimental parameters, such as sample loading time, sample flow rate, sample ph, eluent flow rate, eluent concentration, and interfering ions, were investigated systematically. under the optimum conditions, the detection limits (three times of standard deviations of blank by 7 reiterations) of la, tb. and ho were found to be 2.2, 1.6, and 2.8 mu g l(-1), with enrichment factors of 17.1, 11.1, and 10.2, respectively. relative standard deviations for the determination of the target rees were 3.6%, 1.3%, and 1.4%, respectively (n = 7). the developed method was validated by the analysis of la, tb, and ho in certified reference material (gbw07313, marine sediment) and high purity ree oxide samples. (c) 2011 elsevier b.v. all rights reserved. |
收录类别 | SCI收录期刊论文 |
语种 | 英语 |
公开日期 | 2012-06-08 |
源URL | [http://ir.ciac.jl.cn/handle/322003/44270] ![]() |
专题 | 长春应用化学研究所_长春应用化学研究所知识产出_期刊论文 |
推荐引用方式 GB/T 7714 | Zhang JL,Cheng RM,Tong SS,et al. Microwave plasma torch-atomic emission spectrometry for the on-line determination of rare earth elements based on flow injection preconcentration by TiO(2)-graphene composite[J]. talanta,2011,86:114-120. |
APA | Zhang JL.,Cheng RM.,Tong SS.,Gu XW.,Quan XJ.,...&Jia JB.(2011).Microwave plasma torch-atomic emission spectrometry for the on-line determination of rare earth elements based on flow injection preconcentration by TiO(2)-graphene composite.talanta,86,114-120. |
MLA | Zhang JL,et al."Microwave plasma torch-atomic emission spectrometry for the on-line determination of rare earth elements based on flow injection preconcentration by TiO(2)-graphene composite".talanta 86(2011):114-120. |
入库方式: OAI收割
来源:长春应用化学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。