中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Solid-State Label-Free Integrated Aptasensor Based on Graphene-Mesoporous Silica-Gold Nanoparticle Hybrids and Silver Microspheres

文献类型:期刊论文

作者Guo SJ ; Du Y ; Yang X ; Dong SJ ; Wang EK
刊名analytical chemistry
出版日期2011
卷号83期号:20页码:8035-8040
关键词ELECTROCHEMICAL APTASENSOR FLUORESCENCE DETECTION COLORIMETRIC DETECTION SENSITIVE DETECTION SMALL MOLECULES FUEL-CELLS APTAMER DNA BIOSENSOR SELECTION
ISSN号0003-2700
通讯作者dong sj
中文摘要taking advantage of strand-displacement dna polymerization and parallel-motif dna triplex system as dual amplifications, a new electrochemical label-free integrated aptasensor based on silver microspheres (smss) as a separation element and graphene-mesoporous silica-gold nanoparticle (np) hybrids (gsghs) as an enhanced element of the sensing platform was first reported. in this sensing design (schematic representation of the sensing procedure for adenosine triphosphate detection, scheme 1 in manuscript text), which contains an enhanced three-step magnification process, smss with "clean" surface were first used to separate the undesirable aptamer and aptamer-adenosine triphosphate (atp) complex attached on smss surface after aptamer-atp interaction, which lead to the detachment of blocker dna into the solution phase. then, under the assistance of blocker dna, an amplified method based on the inherent signal-transduction mechanism of the hairpin probe and strand-displacement property of dna polymerase was introduced. the obtained duplex dna was used to hybridize with an acceptor dna assembled on electrode to form triplex dna, which could bring a more obvious detection signal compared with the duplex dna without the amplification. the electrochemical signal came from the gsgh-based enhanced sensing interface containing positively charged ferrocene-appended poly(ethyleneimine) (fc-pei). using the above multiple effects, we could achieve the sensitive analysis of a model small molecule-atp (an important "molecular currency" of intracellular energy transfer) in a wide detection range from 0.05 nm to 56.5 nm with the detection limit of 0.023 nm.
收录类别SCI收录期刊论文
语种英语
WOS记录号WOS:000295817500065
公开日期2012-06-08
源URL[http://ir.ciac.jl.cn/handle/322003/44284]  
专题长春应用化学研究所_长春应用化学研究所知识产出_期刊论文
推荐引用方式
GB/T 7714
Guo SJ,Du Y,Yang X,et al. Solid-State Label-Free Integrated Aptasensor Based on Graphene-Mesoporous Silica-Gold Nanoparticle Hybrids and Silver Microspheres[J]. analytical chemistry,2011,83(20):8035-8040.
APA Guo SJ,Du Y,Yang X,Dong SJ,&Wang EK.(2011).Solid-State Label-Free Integrated Aptasensor Based on Graphene-Mesoporous Silica-Gold Nanoparticle Hybrids and Silver Microspheres.analytical chemistry,83(20),8035-8040.
MLA Guo SJ,et al."Solid-State Label-Free Integrated Aptasensor Based on Graphene-Mesoporous Silica-Gold Nanoparticle Hybrids and Silver Microspheres".analytical chemistry 83.20(2011):8035-8040.

入库方式: OAI收割

来源:长春应用化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。