Microcantilever Biosensor on the Biotin-avidin Interaction

文献类型:期刊论文

作者Zhang HY ; Pan HQ ; Tang JL ; Zhang BL
刊名acta chimica sinica
出版日期2011
卷号69期号:2页码:243-246
关键词SELF-ASSEMBLED MONOLAYER PROTEINS
ISSN号0567-7351
通讯作者zhang hy
中文摘要the dynamic interaction process of biotin-avidin was investigated by biotin covalently modified microcantilever sensor in real-time in a flowing cell. the specific interaction was confirmed by the evidence that the avidin layer can be mechanically removed with atomic force microscopy nanolithography. the deflection of the modified cantilever increased with concentration of avidin. microcantilever biosensor provides a good method to explore novel label-free technology and monitor various interactions between biomolecules.
收录类别SCI收录期刊论文
语种中文
WOS记录号WOS:000287907800022
公开日期2012-06-11
源URL[http://ir.ciac.jl.cn/handle/322003/44865]  
专题长春应用化学研究所_长春应用化学研究所知识产出_期刊论文
推荐引用方式
GB/T 7714
Zhang HY,Pan HQ,Tang JL,et al. Microcantilever Biosensor on the Biotin-avidin Interaction[J]. acta chimica sinica,2011,69(2):243-246.
APA Zhang HY,Pan HQ,Tang JL,&Zhang BL.(2011).Microcantilever Biosensor on the Biotin-avidin Interaction.acta chimica sinica,69(2),243-246.
MLA Zhang HY,et al."Microcantilever Biosensor on the Biotin-avidin Interaction".acta chimica sinica 69.2(2011):243-246.