Speciation Analysis of Organotin Compounds in Sediment by Hyphenated Technique of High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
文献类型:期刊论文
作者 | Yu Zhen-Hua1,2; Zhang Jie1; Wang Xiao-Ru3 |
刊名 | CHINESE JOURNAL OF ANALYTICAL CHEMISTRY |
出版日期 | 2011-04-01 |
卷号 | 39期号:4页码:544-547 |
ISSN号 | 0253-3820 |
关键词 | High performance liquid chromatography-inductively coupled plasma mass spectrometry Organotin compounds Speciation Sediment |
中文摘要 | The hyphenated technique of high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) was applied to the simultaneous determination of five organotin compounds in the sediment samples. Agilent TC-C18 column was selected, mobile phase of the HPLC was CH(3)CN : H(2)O : CH(3)COOH = 65 : 23 : 12 (V/V), 0. 05% triethylamine (TEA), pH=3. 0 at flow rate Of 0. 6 mL/min. 30% O(2)/Ar mixed gas was added to the make-up gas, which not only reduced the carbon build-up on the cones, but also protected the cones. To reduce solvent loading on the plasma, the double-pass spray-chamber was peltier cooled to-5 degrees C. The high RF power (1500 W) helped the samples to decompose completely. A mix standard solution of five mixed organotin compounds from 100 mu g/L to 1 mu g/L was used for the method assessment. The experimental results indicate that the correlaticin coefficient of calibration curves (R(2)) for each organotin compound was over 0. 998. The international standard reference PACS-2 samples were treated by supersonic extraction with mobile phase added 0. 2% tropolone. Two organotin compounds including dibutyltin chloride (DBT) and tributyltin chloride (TBT) were detected with method mentioned above. The values of dibutyltin chloride (DBT) and tributyltin chloride (TBT) were 0. 99 and 0. 83 mg/kg, respectively. The results showed good accordance with the certified values. The recoveries from the standard addition for five organtins were over 80%. |
英文摘要 | The hyphenated technique of high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) was applied to the simultaneous determination of five organotin compounds in the sediment samples. Agilent TC-C18 column was selected, mobile phase of the HPLC was CH(3)CN : H(2)O : CH(3)COOH = 65 : 23 : 12 (V/V), 0. 05% triethylamine (TEA), pH=3. 0 at flow rate Of 0. 6 mL/min. 30% O(2)/Ar mixed gas was added to the make-up gas, which not only reduced the carbon build-up on the cones, but also protected the cones. To reduce solvent loading on the plasma, the double-pass spray-chamber was peltier cooled to-5 degrees C. The high RF power (1500 W) helped the samples to decompose completely. A mix standard solution of five mixed organotin compounds from 100 mu g/L to 1 mu g/L was used for the method assessment. The experimental results indicate that the correlaticin coefficient of calibration curves (R(2)) for each organotin compound was over 0. 998. The international standard reference PACS-2 samples were treated by supersonic extraction with mobile phase added 0. 2% tropolone. Two organotin compounds including dibutyltin chloride (DBT) and tributyltin chloride (TBT) were detected with method mentioned above. The values of dibutyltin chloride (DBT) and tributyltin chloride (TBT) were 0. 99 and 0. 83 mg/kg, respectively. The results showed good accordance with the certified values. The recoveries from the standard addition for five organtins were over 80%. |
学科主题 | Chemistry |
收录类别 | SCI |
原文出处 | 10.3724/SP.J.1096.2011.00544 |
语种 | 英语 |
WOS记录号 | WOS:000292345600020 |
公开日期 | 2012-07-03 |
源URL | [http://ir.qdio.ac.cn/handle/337002/11946] |
专题 | 海洋研究所_实验海洋生物学重点实验室 |
作者单位 | 1.Chinese Acad Sci, Inst Oceanol, Qingdao 266071, Peoples R China 2.Qingdao Ctr Dis Control & Prevent, Qingdao 266033, Peoples R China 3.State Ocean Adm, Inst Oceanog 1, Qingdao 266061, Peoples R China |
推荐引用方式 GB/T 7714 | Yu Zhen-Hua,Zhang Jie,Wang Xiao-Ru. Speciation Analysis of Organotin Compounds in Sediment by Hyphenated Technique of High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2011,39(4):544-547. |
APA | Yu Zhen-Hua,Zhang Jie,&Wang Xiao-Ru.(2011).Speciation Analysis of Organotin Compounds in Sediment by Hyphenated Technique of High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,39(4),544-547. |
MLA | Yu Zhen-Hua,et al."Speciation Analysis of Organotin Compounds in Sediment by Hyphenated Technique of High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 39.4(2011):544-547. |
入库方式: OAI收割
来源:海洋研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。