Measurement of instantaneous temperature in shock-loaded nonmetallic solids

文献类型:期刊论文

作者Gao JX(高举贤); Bai RS(白蓉裳); Zheng ZM(郑哲敏)
刊名Journal of Applied Physics
出版日期1990
卷号67期号:5页码:2272-2277
ISSN号0021-8979
通讯作者GAO, JX (reprint author), ACAD SINICA,INST MECH,POB 2251,BEIJING 100080,PEOPLES R CHINA.
中文摘要The feasibility of direct measurement of temperature in shock-loaded, nonmetallic solids within microseconds using a foil thermocouple of 200 Å thickness has been studied over a range of pressure from 0.5 to 4 GPa. The foil thermocouple and thermopile (200 Å thickness) were designed and used to measure the temperature rise in shock-compressed polymethylmethacrylate (PMMA). The method used to manufacture the gauges is spelled out in detail in this paper. The results agree with calculated PMMA temperatures when the shock pressure is below 2.2 GPa. Above this pressure the measured temperature rise is far higher than the calculated values. This result appears to be very similar to that obtained earlier by Bloomquist and Sheffield.
类目[WOS]Physics, Applied
研究领域[WOS]Physics
收录类别SCI
语种英语
WOS记录号WOS:A1990CR96900012
公开日期2009-08-03 ; 2010-08-20
源URL[http://dspace.imech.ac.cn/handle/311007/39600]  
专题力学研究所_力学所知识产出(1956-2008)
推荐引用方式
GB/T 7714
Gao JX,Bai RS,Zheng ZM. Measurement of instantaneous temperature in shock-loaded nonmetallic solids[J]. Journal of Applied Physics,1990,67(5):2272-2277.
APA 高举贤,白蓉裳,&郑哲敏.(1990).Measurement of instantaneous temperature in shock-loaded nonmetallic solids.Journal of Applied Physics,67(5),2272-2277.
MLA 高举贤,et al."Measurement of instantaneous temperature in shock-loaded nonmetallic solids".Journal of Applied Physics 67.5(1990):2272-2277.

入库方式: OAI收割

来源:力学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。