中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Analysis of field of view limited by a multi-line X-ray source and its improvement for grating interferometry

文献类型:期刊论文

作者Du, Yang1,2; Huang, Jianheng1; Lin, Danying1; Niu, Hanben1
刊名analytical and bioanalytical chemistry
出版日期2012-08-01
卷号404期号:3页码:793-797
关键词X-ray phase contrast imaging Grating interferometry Multi-line X-ray source Field of view
ISSN号1618-2642
产权排序2
合作状况国内
英文摘要x-ray phase-contrast imaging based on grating interferometry is a technique with the potential to provide absorption, differential phase contrast, and dark-field signals simultaneously. the multi-line x-ray source used recently in grating interferometry has the advantage of high-energy x-rays for imaging of thick samples for most clinical and industrial investigations. however, it has a drawback of limited field of view (fov), because of the axial extension of the x-ray emission area. in this paper, we analyze the effects of axial extension of the multi-line x-ray source on the fov and its improvement in terms of fresnel diffraction theory. computer simulation results show that the fov limitation can be overcome by use of an alternative x-ray tube with a specially designed multi-step anode. the fov of this newly designed x-ray source can be approximately four times larger than that of the multi-line x-ray source in the same emission area. this might be beneficial for the applications of x-ray phase contrast imaging in materials science, biology, medicine, and industry.
WOS标题词science & technology ; life sciences & biomedicine ; physical sciences
类目[WOS]biochemical research methods ; chemistry, analytical
研究领域[WOS]biochemistry & molecular biology ; chemistry
关键词[WOS]computed-tomography ; fabrication
收录类别SCI ; EI
语种英语
WOS记录号WOS:000307251900022
公开日期2012-12-03
源URL[http://ir.opt.ac.cn/handle/181661/20413]  
专题西安光学精密机械研究所_研究生部
作者单位1.Shenzhen Univ, Key Lab Optoelect Devices & Syst, Minist Educ & Guangdong Prov, Shenzhen 518060, Peoples R China
2.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China
推荐引用方式
GB/T 7714
Du, Yang,Huang, Jianheng,Lin, Danying,et al. Analysis of field of view limited by a multi-line X-ray source and its improvement for grating interferometry[J]. analytical and bioanalytical chemistry,2012,404(3):793-797.
APA Du, Yang,Huang, Jianheng,Lin, Danying,&Niu, Hanben.(2012).Analysis of field of view limited by a multi-line X-ray source and its improvement for grating interferometry.analytical and bioanalytical chemistry,404(3),793-797.
MLA Du, Yang,et al."Analysis of field of view limited by a multi-line X-ray source and its improvement for grating interferometry".analytical and bioanalytical chemistry 404.3(2012):793-797.

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。