Analysis of field of view limited by a multi-line X-ray source and its improvement for grating interferometry
文献类型:期刊论文
作者 | Du, Yang1,2; Huang, Jianheng1; Lin, Danying1; Niu, Hanben1 |
刊名 | analytical and bioanalytical chemistry
![]() |
出版日期 | 2012-08-01 |
卷号 | 404期号:3页码:793-797 |
关键词 | X-ray phase contrast imaging Grating interferometry Multi-line X-ray source Field of view |
ISSN号 | 1618-2642 |
产权排序 | 2 |
合作状况 | 国内 |
英文摘要 | x-ray phase-contrast imaging based on grating interferometry is a technique with the potential to provide absorption, differential phase contrast, and dark-field signals simultaneously. the multi-line x-ray source used recently in grating interferometry has the advantage of high-energy x-rays for imaging of thick samples for most clinical and industrial investigations. however, it has a drawback of limited field of view (fov), because of the axial extension of the x-ray emission area. in this paper, we analyze the effects of axial extension of the multi-line x-ray source on the fov and its improvement in terms of fresnel diffraction theory. computer simulation results show that the fov limitation can be overcome by use of an alternative x-ray tube with a specially designed multi-step anode. the fov of this newly designed x-ray source can be approximately four times larger than that of the multi-line x-ray source in the same emission area. this might be beneficial for the applications of x-ray phase contrast imaging in materials science, biology, medicine, and industry. |
WOS标题词 | science & technology ; life sciences & biomedicine ; physical sciences |
类目[WOS] | biochemical research methods ; chemistry, analytical |
研究领域[WOS] | biochemistry & molecular biology ; chemistry |
关键词[WOS] | computed-tomography ; fabrication |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000307251900022 |
公开日期 | 2012-12-03 |
源URL | [http://ir.opt.ac.cn/handle/181661/20413] ![]() |
专题 | 西安光学精密机械研究所_研究生部 |
作者单位 | 1.Shenzhen Univ, Key Lab Optoelect Devices & Syst, Minist Educ & Guangdong Prov, Shenzhen 518060, Peoples R China 2.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China |
推荐引用方式 GB/T 7714 | Du, Yang,Huang, Jianheng,Lin, Danying,et al. Analysis of field of view limited by a multi-line X-ray source and its improvement for grating interferometry[J]. analytical and bioanalytical chemistry,2012,404(3):793-797. |
APA | Du, Yang,Huang, Jianheng,Lin, Danying,&Niu, Hanben.(2012).Analysis of field of view limited by a multi-line X-ray source and its improvement for grating interferometry.analytical and bioanalytical chemistry,404(3),793-797. |
MLA | Du, Yang,et al."Analysis of field of view limited by a multi-line X-ray source and its improvement for grating interferometry".analytical and bioanalytical chemistry 404.3(2012):793-797. |
入库方式: OAI收割
来源:西安光学精密机械研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。