中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Magnetic Resonance Imaging Study of New PAGAT Polymer Gel Dosimeter

文献类型:期刊论文

作者Zhao Yun; He Cheng-Fa; Liu Yan; Yang Jin-Jun; Wei Ping-Qiang; Lan Bo; Cui Jiang-Wei; Fei Wu-Xiong; Li Mao-Shun; Wang Fei
刊名Atomic Energy Science and Technology
出版日期2011
卷号45期号:3页码:360-364
关键词Amides Chlorine compounds Dosimeters Gels Hydrogels Magnetic resonance imaging Methanol Polymers Resonance
ISSN号10006931
中文摘要使用丙烯酰胺、明胶、交联剂、除氧剂和甲醛等在常氧条件下制备出一种新型的PAGAT聚合物凝胶剂量计。实验结果表明:剂量计的磁共振横向弛豫率随吸收剂量的增加而增大,经计算,得出了剂量计的探测下限;剂量计样品的批均匀性好于3.2%,且剂量响应在0.05~1.00Gy/s之间基本与剂量率无关。此外,使用该剂量计对异质界面剂量分布的测量结果以及剂量增强效应进行了分析。
英文摘要A new type of PAGAT polymer gel dosimeter, containing acrylamide, gelatin, N, N'-methylene-bisacrylamide (BIS), tetrakis (hydroxymethyl) phosphonium chloride (THPC) and formaldehyde, was prepared under normal atmospheric conditions. The results show that its transverse relaxation ratio increases with the absorbed dose and its minimum detection limit is given. The dosimeter has good uniformity of one batch (better than 3.2%) and negligible dose-rate dependence in the range of 0.05-1.00 Gy/s. Using the gel dosimeter, the dose distribution of a heterogeneous interface was obtained and the dose enhancement effect was analyzed.
公开日期2012-11-29
源URL[http://ir.xjipc.cas.cn/handle/365002/1428]  
专题新疆理化技术研究所_材料物理与化学研究室
固体辐射物理研究室
作者单位Xinjiang Technical Institute of Physics & Chemistry, Chinese Academy of Sciences, Urumqi, Xinjiang 830011, China;CTMR Department, The Fifth Teaching Hospital of Xinjiang Medical University, Urumqi, Xinjiang 830011, China;CTMR Department, The Fifth Teaching Hospital of Xinjiang Medical University, Urumqi, Xinjiang 830011, China
推荐引用方式
GB/T 7714
Zhao Yun,He Cheng-Fa,Liu Yan,et al. Magnetic Resonance Imaging Study of New PAGAT Polymer Gel Dosimeter[J]. Atomic Energy Science and Technology,2011,45(3):360-364.
APA Zhao Yun.,He Cheng-Fa.,Liu Yan.,Yang Jin-Jun.,Wei Ping-Qiang.,...&Wang Fei.(2011).Magnetic Resonance Imaging Study of New PAGAT Polymer Gel Dosimeter.Atomic Energy Science and Technology,45(3),360-364.
MLA Zhao Yun,et al."Magnetic Resonance Imaging Study of New PAGAT Polymer Gel Dosimeter".Atomic Energy Science and Technology 45.3(2011):360-364.