中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
不同60Co γ剂量率下10位双极D/A转换器的总剂量效应

文献类型:期刊论文

作者王义元; 陆妩; 任迪远; 郑玉展; 高博; 李鹏伟; 于跃
刊名原子能科学技术
出版日期2009
卷号43期号:10页码:951-955
关键词双极数模转换器 剂量率 电离效应 低剂量率损伤增强效应
ISSN号10006931
中文摘要为探索电离辐射对数模混合电路的影响,对国产10位双极D/A转换器在60Co γ射线不同剂量率辐照下的电离辐射效应及退火特性进行研究。结果表明:D/A转换器对辐照剂量率十分敏感,在大剂量率辐照时,电路功能正常,各功能参数变化较小;在低剂量率辐照下,各参数变化显著,电路功能出现异常,表现出明显的低剂量率损伤增强效应。最后,结合空间电荷模型对其电离辐射损伤机理进行了初步探讨。
英文摘要In order to find the responses of digital-to-analog (D/A) converters in ionizing radiation environment, total dose effect and room-temperature annealing behavior of a 10-bit bipolar D/A converter irradiated by different 60Co γ dose rates were investigated. The D/A converter is quite sensitive to dose rates, and its functions are normal at high dose rate irradiation. While under low-dose-rate case, it works out of the way and many parameters go beyond its permitted range. Thus, it exhibits an enhanced low-dose-rate sensitivity effect. Finally, possible mechanism was discussed based on the space charge model.
公开日期2012-11-29
源URL[http://ir.xjipc.cas.cn/handle/365002/1812]  
专题新疆理化技术研究所_材料物理与化学研究室
作者单位中国科学院新疆理化技术研究所;中国科学院研究生院
推荐引用方式
GB/T 7714
王义元,陆妩,任迪远,等. 不同60Co γ剂量率下10位双极D/A转换器的总剂量效应[J]. 原子能科学技术,2009,43(10):951-955.
APA 王义元.,陆妩.,任迪远.,郑玉展.,高博.,...&于跃.(2009).不同60Co γ剂量率下10位双极D/A转换器的总剂量效应.原子能科学技术,43(10),951-955.
MLA 王义元,et al."不同60Co γ剂量率下10位双极D/A转换器的总剂量效应".原子能科学技术 43.10(2009):951-955.

入库方式: OAI收割

来源:新疆理化技术研究所

浏览0
下载0
收藏0
其他版本