英文摘要The performance of protein separation using the figure-8 column configuration in centrifugal countercurrent chromatography was investigated under various flow rates and revolution speeds. The separation was performed with a two-phase solvent system composed of polyethylene glycol 1000/potassium phosphate each at 12.5% (w/w) in water and with lysozyme and myoglobin as test samples. In order to improve tracing of the elution curve, a hollow fiber membrane dialyzer was inserted at the inlet of the UV detector. The results showed that the retention of stationary phase (Sf) and resolution (Rs) increased with decreased flow rate and increased revolution speed. The highest Rs of approximately 1 was obtained at a flow rate of 0.01 mL/min under a revolution speed of 1200 rpm with a 3.4 mL capacity column.
学科主题Biochemistry & Molecular Biology ; Chemistry
WOS记录号WOS:000298530200004
公开日期2012-11-29
源URL[http://ir.xjipc.cas.cn/handle/365002/1449]  
专题新疆理化技术研究所_省部共建新疆特有药用资源利用重点实验室
作者单位NHLBI, Bioseparat Technol Lab, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA;Chinese Acad Sci, Key Lab Chem Plant Resources Arid Reg, Xinjiang Tech Inst Phys & Chem, Urumqi 830011, Peoples R China
推荐引用方式
GB/T 7714
Yang Yi,Gu Dongyu,Aisa Haji Akber,et al. Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography[J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,2011,879(32):3802-3805.
APA Yang Yi,Gu Dongyu,Aisa Haji Akber,&Ito Yoichiro.(2011).Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,879(32),3802-3805.
MLA Yang Yi,et al."Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 879.32(2011):3802-3805.

入库方式: OAI收割

来源:新疆理化技术研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。