中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
热门
Analysis of estrogens in environmental waters using polymer monolith in-polyether ether ketone tube solid-phase microextraction combined with high-performance liquid chromatography

文献类型:期刊论文

作者Wen, Yi; Zhou, Bing-Sheng; Xu, Ying; Jin, Shi-Wei; Feng, Yu-Qi
刊名JOURNAL OF CHROMATOGRAPHY A
出版日期2006-11-10
卷号1133期号:1-2页码:21-28
关键词endocrine disruptors environmental water polymer monolith in-polyether ether ketone tube solid-phase microextraction poly(acrylamide-vinylpyridine-N HPLC N ''-methylene bisacrylamide) monolith
ISSN号0021-9673
通讯作者Feng, YQ, Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
中文摘要A simple, rapid and sensitive on-line method for simultaneous determination of four endocrine disruptors (17 beta-estradiol, estriol, bisphenol A and 17 alpha-ethinylestradiol) in environmental waters was developed by coupling in-tube solid-phase microextraction (SPME) to high-performance liquid chromatography (HPLC) with fluorescence detection (FLD). A poly(acrylamide-vinylpyridine-NAP-methylene bisacrylamide) monolith, synthesized inside a polyether ether ketone (PEEK) tube, was selected as the extraction medium. To achieve optimum extraction performance, several parameters were investigated, including extraction flow-rate, extraction time, and pH value, inorganic salt and organic solvent content of the sample matrix. By simply filtered with nylon membrane filter and adjusting the pH of samples to 6.0 with phosphoric acid, the sample solution then could be directly injected into the device for extraction. Low detection limits (S/N = 3) and quantification limits (S/N = 10) of the proposed method were achieved in the range of 0.006-0.10 ng/mL and 0.02-0.35 ng/mL from spiked lake waters, respectively. The calibration curves of four endocrine disruptors showed good linearity ranging from quantification limits to 50 ng/mL with a linear coefficient R-2 value above 0.9913. Good method reproducibility was also found by intra- and inter-day precisions, yielding the RSDs less than 12 and 9.8%, respectively. Finally, the proposed method was successfully applied to the determination of these compounds in several environmental waters. (c) 2006 Elsevier B.V. All rights reserved.
英文摘要A simple, rapid and sensitive on-line method for simultaneous determination of four endocrine disruptors (17 beta-estradiol, estriol, bisphenol A and 17 alpha-ethinylestradiol) in environmental waters was developed by coupling in-tube solid-phase microextraction (SPME) to high-performance liquid chromatography (HPLC) with fluorescence detection (FLD). A poly(acrylamide-vinylpyridine-NAP-methylene bisacrylamide) monolith, synthesized inside a polyether ether ketone (PEEK) tube, was selected as the extraction medium. To achieve optimum extraction performance, several parameters were investigated, including extraction flow-rate, extraction time, and pH value, inorganic salt and organic solvent content of the sample matrix. By simply filtered with nylon membrane filter and adjusting the pH of samples to 6.0 with phosphoric acid, the sample solution then could be directly injected into the device for extraction. Low detection limits (S/N = 3) and quantification limits (S/N = 10) of the proposed method were achieved in the range of 0.006-0.10 ng/mL and 0.02-0.35 ng/mL from spiked lake waters, respectively. The calibration curves of four endocrine disruptors showed good linearity ranging from quantification limits to 50 ng/mL with a linear coefficient R-2 value above 0.9913. Good method reproducibility was also found by intra- and inter-day precisions, yielding the RSDs less than 12 and 9.8%, respectively. Finally, the proposed method was successfully applied to the determination of these compounds in several environmental waters. (c) 2006 Elsevier B.V. All rights reserved.
WOS标题词Science & Technology ; Life Sciences & Biomedicine ; Physical Sciences
学科主题Biochemical Research Methods; Chemistry, Analytical
类目[WOS]Biochemical Research Methods ; Chemistry, Analytical
研究领域[WOS]Biochemistry & Molecular Biology ; Chemistry
关键词[WOS]TANDEM MASS-SPECTROMETRY ; BAR SORPTIVE EXTRACTION ; ENDOCRINE DISRUPTING CHEMICALS ; ONLINE PRETREATMENT DEVICE ; PERSONAL-CARE PRODUCTS ; ON-FIBER SILYLATION ; GAS-CHROMATOGRAPHY ; BISPHENOL-A ; WASTE-WATER ; SITU DERIVATIZATION
收录类别SCI
语种英语
WOS记录号WOS:000241772800003
公开日期2010-10-13
源URL[http://ir.ihb.ac.cn/handle/152342/8804]  
专题水生生物研究所_中科院水生所知识产出(2009年前)_期刊论文
作者单位1.Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
2.Chinese Acad Sci, State Key Lab Freshwater Ecol & Biotechnol, Inst Hydrobiol, Wuhan 430072, Peoples R China
推荐引用方式
GB/T 7714
Wen, Yi,Zhou, Bing-Sheng,Xu, Ying,et al. Analysis of estrogens in environmental waters using polymer monolith in-polyether ether ketone tube solid-phase microextraction combined with high-performance liquid chromatography[J]. JOURNAL OF CHROMATOGRAPHY A,2006,1133(1-2):21-28.
APA Wen, Yi,Zhou, Bing-Sheng,Xu, Ying,Jin, Shi-Wei,&Feng, Yu-Qi.(2006).Analysis of estrogens in environmental waters using polymer monolith in-polyether ether ketone tube solid-phase microextraction combined with high-performance liquid chromatography.JOURNAL OF CHROMATOGRAPHY A,1133(1-2),21-28.
MLA Wen, Yi,et al."Analysis of estrogens in environmental waters using polymer monolith in-polyether ether ketone tube solid-phase microextraction combined with high-performance liquid chromatography".JOURNAL OF CHROMATOGRAPHY A 1133.1-2(2006):21-28.

入库方式: OAI收割

来源:水生生物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。